INSTALLATION INSTRUCTIONS
Once the logic controller enclosure is
secured to the structure—locate the drive
unit cable and the electronic limit cable.
Fit the electronic limit cable plug through the
hole provided at the bottom of the
enclosure—use care to ensure correct
fitment
Fit the cable gland & strain relief bushing to
the four wire drive unit cable and fit the cable
through the hole provided at the bottom of
the enclosure—remove the plug in section of
the terminal and connect the wires in
accordance with the detail provided
As per factory issue—the logic controller is
designed to operate with momentary contact
to OPEN and constant contact to CLOSE
STEP 5.
“fitting the logic controller….(continued)”
Cable gland & strain relief bushing