Questions and Answers

  • P
    Phillip WhiteAug 19, 2025
    How to troubleshoot a Jasic Welding System that shows no response after start up?
    • A
      Anthony HensleyAug 19, 2025
      If your Jasic Welding System shows no response after startup, it could be due to several reasons. First, ensure the input voltage meets the required specifications. Next, verify that the power cord is correctly connected and not damaged. Finally, make sure the emergency stop button on the panel is not pressed.
  • R
    rcopelandAug 21, 2025
    Why is the brass nozzle burnt on my Jasic Welding System?
    • V
      veronica54Aug 21, 2025
      If the brass nozzle on your Jasic Welding System is burnt, it could be due to the laser light not being centered or the focal length adjustment of the graded tube being inappropriate. Check if the red light emission position and spot size are normal. If the position is incorrect, adjust the red light. If the spot size is not appropriate, adjust the focal length of the graded tube.
  • M
    Misty StoneAug 23, 2025
    What to do if the laser weakens during welding with my Jasic Welding System?
    • E
      Elizabeth FernandezAug 23, 2025
      If your Jasic Welding System's laser weakens during welding, it may be due to damage to the protective lens, which prevents the laser from focusing correctly. Replace the protective lens and investigate the cause of the lens damage to prevent recurrence.
  • T
    timothybarronAug 26, 2025
    What to do if there is no wire feeding after pressing the torch trigger on my Jasic LS-15000F Welding System?
    • J
      Jason McleanAug 26, 2025
      If you press the torch trigger on your Jasic Welding System and there's no wire feeding, it could be because the wire feeder isn't properly connected to the welder or the signal cable is damaged. Ensure the wire feeder is correctly connected. If the signal cable is damaged, replace it.
  • J
    jason73Aug 27, 2025
    Why does the welding torch protective lens often burn out on my Jasic LS-15000F?
    • C
      Christopher TuckerAug 28, 2025
      If your Jasic Welding System's welding torch protective lens often burns out, it may be due to incorrect welding technique causing laser reflection that damages the lens. Ensure the welding torch is positioned at a 45-degree angle to the plate, rather than perpendicular.
  • L
    Lauren WhiteAug 29, 2025
    What to do if the water cooler overheat alarm is on in my Jasic LS-15000F Welding System?
    • C
      Colleen TorresAug 30, 2025
      If the water cooler on your Jasic Welding System is showing an overheat alarm, it means the internal coolant temperature has exceeded the set value. Stop welding, disable the laser enablement button, and resume welding after the alarm clears.
  • D
    Debra PaulSep 1, 2025
    What to do if there is no light emission after pressing the torch trigger on my Jasic LS-15000F Welding System?
    • C
      Charles CortezSep 1, 2025
      If you press the torch trigger on your Jasic Welding System and there is no light emission, it could be because the enablement button or the laser button on the display is not enabled, or the earth clamp is not clamped. Enter the diagnosis interface and check the various parameters to ensure that all preparation signals are normal and the safety ground lock is connected.
  • W
    William GarciaSep 3, 2025
    How to prevent lens burnout due to dust in my Jasic LS-15000F Welding System?
    • S
      Shelia WashingtonSep 3, 2025
      If your Jasic Welding System's environment is too dusty, and the lens is contaminated with dust, resulting in burnout, the welding machine should be stored in a room with little dust, and the nozzle should be protected from dust when the welding torch is not in use.
  • C
    cmooreSep 5, 2025
    What to do if the permission to use the controller has expired on my Jasic Welding System?
    • R
      Robert FernandezSep 5, 2025
      If your Jasic Welding System displays that the permission to use the controller has expired, contact the manufacturer to provide a password for reactivation.
  • B
    Brian DiazSep 7, 2025
    What causes overheat due to insufficient water level in my Jasic LS-15000F?
    • D
      Daniel SteeleSep 7, 2025
      If the coolant level of water cooler of your Jasic Welding System is insufficient, leading to overheat, check the coolant level of water cooler, which should be in the standard area.