The JASIC TIG 200 Pulse AC/DC is a technologically advanced
single-phase inverter power source suitable for medium to large
production work. The innovative and user-friendly analog panel
allows full control of the welding parameters.
The excellent technical characteristics of the 200 AC/DC make it
an ideal choice for professionally qualified TIG welders that require
precise and reliable performance.
Order Code: 14.10.00200001 TIG 200P AC/DC Analog
TIG Pulse AC/DC with analog control
• Digital display
• Peak current control, 2T/4T
• Pre-post flow time, up/down slope
• Pulse adjustment
• Pulse frequency, pulse duty, arc force, cleaning width
• Remote control interface
• AC function for aluminium and aluminium alloys
• DC TIG function for carbon steel,
copper and non-ferrous metals
• Smooth arc and stable welding performance
• Generator friendly
Ieff
AC 230V - 50/60 Hz 9.4
18A
70 Class: IP21S/B
AC: 30 - 185
DC: 10 - 185
185A @ 20%
Dimensions LxWxH
570 x 335 x 440
25
1
Digital Display
10
Peak Current
2
Power On/O Indicator
11
Pulse Low Current
3
Warning Indicator
12
Down Slope Time
4
Power On/O Switch
13
Arc Force
5
2T/4T/Spot Selection Switch
14
Pulse Frequency
6
Process Selection Switch
15
Pulse Duty
7
AC/DC Switch
16
Wave Balance
8
Pulse On/O Switch
17
Post Flow Gas
9
Gas Pre-Flow Time
1
2
3
4
5 6
7 8
9 10 11 12
13 14 15 16 17
List Price €880.00
Accessories/Optional Items
Part Number Description € List Price
* 14.00.00203000 Earth Clamp and 3m Cable 19.00
14.00.00000203 Electrode Holder and 3m Cable 28.00
* 14.00.38000000 T26 4m Torch 130.00
14.00.38000001 T26F 4m Torch 134.00
14.00.38080000 T26 8m Torch 170.00
14.00.38080001 T26F 8m Torch 174.00
14.00.00001000 Trolley 250.00
14.00.00000100 Foot Control 42.00
* Comes as Standard
I
n
c
l
u
d
e
d

Questions and Answers

  • J
    Jamie TranAug 15, 2025
    Why does the pedal control malfunction on my Jasic TIG 200P Welding System, but hand control works?
    • N
      nguerraAug 15, 2025
      If the hand control mode works but the pedal control malfunctions on your Jasic Welding System, it could be due to: * A malfunctioning switch on the pedal controller. Replace the pedal controller switch. * A malfunctioning potentiometer on the pedal controller. Replace the 1K potentiometer.
  • C
    Cynthia VegaAug 18, 2025
    Why does my Jasic TIG 200P Welding System have no weld output?
    • J
      Jennifer PayneAug 18, 2025
      If your Jasic Welding System has no weld output when you switch the power on, it could be due to: * An insufficient or shorted power source. Try compensating for the input failure. * A faulty input connection. Reconnect the input. * A failure of the secondary power source inside the equipment. In this case, seek advice from an authorized supplier.
  • A
    Amber SpencerAug 21, 2025
    What to do if the warning indicator light is on for Jasic TIG 200P?
    • A
      Allison ClayAug 21, 2025
      If the warning indicator light is on for your Jasic Welding System, it could be due to: * Over-amperage protection. Switch off the power, let the equipment cool down, and then try operating it again. * Excessive dust accumulation causing a short circuit. Remove the accumulated dust inside the equipment using compressed air. * Malfunctioning internal components. Seek advice from qualified professionals.
  • D
    Desiree SmithAug 25, 2025
    Why is there no gas output on my Jasic TIG 200P Welding System, but current output is present?
    • D
      David Thornton DVMAug 25, 2025
      If your Jasic Welding System has current output but no gas output, the possible causes are: * The electromagnetic valve isn't functioning. Try unblocking the gas nozzle. * A blocked gas nozzle. Replace the nozzle. * Cracked or worn gas hose on the welding torch. Replace the electromagnetic valve. * Disabled, damaged or malfunctioning circuit of the electromagnetic valve. Seek assistance from professionals.
  • H
    haydenheatherAug 28, 2025
    What to do if Jasic TIG 200P Welding System releases electricity but has no current output?
    • A
      Alisha WilkersonAug 28, 2025
      If your Jasic Welding System is releasing electricity but has no current output, check for these issues: * A faulty earth cable connection. Reconnect the earth cable. * A short-circuited torch cable. Reconnect the torch cable.
  • M
    Michael LopezAug 31, 2025
    Why is the current output not adjustable on my Jasic TIG 200P?
    • S
      Sarah ThomasAug 31, 2025
      If the current output on your Jasic Welding System is present but not adjustable, it might be due to: * Incorrect connection of the pedal controller. Ensure the pedal controller is in the correct mode. * A damaged or worn potentiometer in the pedal controller. Replace the potentiometer.
  • D
    David BruceSep 3, 2025
    What to do if the regulator indicates, no sound of releasing electricity, no show of breakdown in Jasic TIG 200P Welding System?
    • N
      Noah FosterSep 4, 2025
      If the regulator indicates activity, but there's no sound of electricity release and no breakdown shown on your Jasic Welding System, check these: * Switch failure. Replace the switch. * Electricity releasing components failure. Adjust the distance between the electricity releasing components. * Misconnections of the air plug. Reconnect the air plug.
  • M
    Miranda ThomasSep 7, 2025
    Why is the earth cable excessively heated on my Jasic TIG 200P?
    • K
      Kimberly GuzmanSep 7, 2025
      If the earth cable of your Jasic Welding System is excessively heated, it is likely due to a failure in the earth lead connections. Reconnect the earth lead.
  • K
    Kathryn AustinSep 12, 2025
    Why is the tungsten damaged on my Jasic Welding System?
    • S
      Sarah NelsonSep 12, 2025
      If the tungsten is damaged on your Jasic Welding System, it may be because the clean width is excessively high. Adjust the Clean Width counterclockwise.

Jasic TIG 200P Specifications

General IconGeneral
Frequency50/60 Hz
Power Factor0.73
Insulation ClassF
Protection ClassIP21S
Welding ProcessTIG
Output Current Range10-200A