29
Step 4: After the above steps are finished, turn on the power supply of the machine, switch on the wire
feeder, and manually feed a wire and make it come out of the wire guide nozzle.
Note: 1) Do not direct the wire guide nozzle at any person or equipment during the wire feeding to
avoid personal injury.
2) Avoid bending the wire guide tube to avoid affecting the wire feeding.
4.6 Switching operation guide
After connecting the overall system, check again for any errors or omissions before startup.
1Open the gas cylinder valve and adjust the gas flow.
2Turn on the switch of the power distribution box, the switch of the rear panel of the machine, and the
switch of the wire feeder in turn.
3Turn on the power switch and emergency stop switch on the front panel. At this time, the machine will
start, and the panel will light up. After startup, check whether the machine and water tank operate
normally and have any alarms.
4Press the manual wire feeding button of the wire feeder to make the welding wire come out of the wire
guide nozzle.
5Disable the laser enablement button to check if the red light is in the center of the brass nozzle and
right to the wire.
6Welding can be carried out after setting welding parameters and wearing protective equipment.
7After welding, disable the laser enablement button, turn off the power switch on the front panel, the
rear panel switch, the power distribution box switch, and then the gas cylinder valve in turn.
8Place the welding torch lightly on the torch holder.
Warning!
When the wire feeder manually feeds the wire, do not direct the guide wire
nozzle to people or equipment to avoid puncture.
When adjusting the red light, it is forbidden to enable the laser
enablement button, to avoid causing injury by light emission.