6
The mains supply voltage should be within ±5% of the rated mains supply voltage. Too low a voltage may
cause poor welding performance. Too high a supply voltage will cause components to overheat and possibly
fail.
CODE REQUIREMENTS FOR ELECTRICAL INPUT CONNECTIONS
This welding machine must be connected to a power source in accordance with applicable electrical codes.
The National Electrical Code provides standards for amperage handling capability of supply conductors
based on duty cycle of the welding source.
If there is any question about the installation meeting applicable electrical code requirements, consult a
qualified electrician.
Do not remove the power cord ground prong.
It is suggested that power cord should be H07RN-F 3X1.5mm
2
(approved according to EN
50525-2-21), welding cable should be H01N2-D 1X10mm
2
and external fuse should be 16A.
The recommended Torch is 25% 100A (approved according to EN 60974-7).
Warning! 16A external fuse or circuit breaker must be used!
Only approved power cord, welding cable, Torch can be used together with the
machine.