EasyManua.ls Logo

Jasic MIG 350P - User Manual

Jasic MIG 350P
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MODEL: MIG 350P (N316), MIG 400P (N317)
INVERTER WELDER
OPERATORS MANUAL
L2040A S C-A4
You Can buy this product at our E-shop:
Šią prekę galite įsigyti mūsų el. parduotuvėje:
BUY NOW
www.e-serpantinas.com

Questions and Answers

  • X
    xsandovalSep 4, 2025
    What to do if the wire feeder doesn't work on my Jasic MIG 350P?
    • R
      Robert GoodSep 4, 2025
      If there is output current when pushing the torch trigger to feed gas, but the wire feeder does not work with your Jasic Welding System, it could be due to: * A broken control cable of the wire feeder. Repair or replace the cable. * A clogged wire feeder. Resolve the clogging problem. * The wire feeder failing. Repair it. * The control PCB or wire feeding power PCB inside the machine failing. Replace the PCB.
  • A
    Amy RodriguezSep 18, 2025
    How to reduce spatter during arc ignition on my Jasic Welding System?
    • R
      ricky85Sep 18, 2025
      If you're experiencing excessive spatter or an overly big molten pool during arc ignition with your Jasic Welding System, it's likely that: * The initial current is too high. Reduce it appropriately. * The initial time is too long. Shorten it properly.
  • P
    Parker WheelerSep 16, 2025
    What to do if there is no response when pushing the torch trigger on my Jasic MIG 350P?
    • C
      Christopher BarnesSep 16, 2025
      If there is no response when pushing the torch trigger on your Jasic Welding System, and the protection LED is off, it could be due to: * The welding torch not being well connected to the wire feeder. Reconnect it. * The control cable of the wire feeder not being well connected to the welding power supply. Reconnect it. * The torch trigger failing. Repair or replace the welding torch.
  • A
    Ashley JamesSep 14, 2025
    Why is the arc easy to break on my Jasic MIG 350P Welding System?
    • V
      Vanessa RhodesSep 14, 2025
      If the arc is easy to break when using your Jasic Welding System, it's likely that the arc breaking voltage is too low. Increase the arc breaking voltage properly.
  • J
    Joshua OconnellSep 12, 2025
    How to fix no display on my Jasic MIG 350P control panel?
    • J
      John GreenSep 12, 2025
      If there is no display on the control panel of your Jasic Welding System after turning it on, it could be due to: * A poorly connected power supply. Reconnect it. * Machine failure. Seek professional assistance.
  • J
    Jacob DixonSep 12, 2025
    Why is my Jasic MIG 350P Welding System wire feeder losing communication?
    • M
      Melissa KellerSep 12, 2025
      If the wire feeder loses communication with the welding power supply of your Jasic Welding System, it may be due to: * A disconnected control cable. Connect the control cable. * A poorly connected control cable. Reconnect the control cable.
  • B
    Blake BlackwellSep 9, 2025
    Why does the electrode holder get so hot on my Jasic Welding System?
    • S
      Sandra TorresSep 9, 2025
      If the electrode holder becomes very hot while using your Jasic Welding System, it's likely because the rated current of the electrode holder is lower than the actual working current. Replace it with one that has a higher rated current.
  • C
    Christine DrakeSep 7, 2025
    Why is the gas regulator not heating up on my Jasic Welding System?
    • M
      Melissa SmithSep 7, 2025
      If the gas regulator cannot be heated on your Jasic Welding System, check the following: * Ensure the heater plug is well connected. * Check for a shorted heater wire and repair if necessary. * See if the resettable fuse inside the machine functions; shut down and restart the machine. * The heater inside the gas regulator might be damaged; consider replacing it.
  • J
    John YatesSep 5, 2025
    Why can't I start a normal arc with my Jasic MIG 350P?
    • L
      Lori SawyerSep 6, 2025
      If you are unable to start a normal arc with your Jasic Welding System, it might be due to a phase failure in the mains power supply or a poorly connected power cord. Address the phase failure or reconnect the power cord.
  • J
    Jennifer RichardsonAug 21, 2025
    Why does my Jasic Welding System display “Err 001”?
    • M
      Mr. Malik MendozaAug 21, 2025
      If the Jasic Welding System displays “Err 001”, it could be due to several reasons: * The mains voltage might be too low. In this case, welding can resume once the voltage recovers. * The mains voltage might be too high. Disconnect the power supply and reconnect it after the voltage stabilizes. * The auxiliary power might have failed. If so, replace the faulty circuit board of the auxiliary power.

Summary

Welding Safety Precautions

Safety Precautions

Comprehensive safety guidelines covering training, electric shock, smoke, arc radiation, fire, hot workpiece, and noise.

Inverter Welder General Description

Model Coding and Product Characteristics

Details model designation, technical overview, and key features of the inverter welder.

Welder Functions and Technical Parameters

Available Functions and Options

Lists welding modes, base metals, gases, and wire types supported by the machine.

Technical and Functional Parameters

Specifies technical data and adjustable functional parameters for MMA and MIG/MAG welding.

Welder Panel Structure and Symbol Guide

Panel Structure Overview

Identifies and labels the main components of the welding machine's front and back panels.

Symbol Descriptions

Explains various symbols used on the front panel, back panel, and nameplate.

Welder Control Panel Operations

Power Supply Monitoring Panel Overview

Provides an overview of the main control panel interface, including displays and selection zones.

Functional Zones: Modes, Material, Gas, Wire

Details selection zones for welding modes, base metal, shielding gas, and wire types.

Welding Process Parameter Selection

Explains selection of process parameters like pre-flow, upslope, peak, base, downslope, crater, and post-flow.

Parameter Adjustment and Operation Modes

Covers current/voltage parameter selection, operation modes, and the adjustment knob.

Gas Check and Channel Management

Explains gas-check functionality and channel management for saving parameters.

Operating the Welder Control Panels

General Operation Steps

Recommended steps for operating the control panel for welding tasks.

MMA Welding Parameters

Details adjustable parameters for MMA welding and their operation.

Standard MIG;MAG Welding Parameters

Lists and explains adjustable parameters for standard MIG/MAG welding.

Pulsed MIG;MAG Welding Parameters

Details adjustable parameters specific to pulsed MIG/MAG welding.

Double Pulse MIG;MAG Parameters

Explains unique parameters for double pulse MIG/MAG welding.

Operation Mode Selection

Guide to selecting different MIG/MAG operation modes and trigger operations.

Welder Cautions and Maintenance

Cautions and Safety Warnings

Important safety precautions and warnings for operating and handling the welding machine.

Maintenance Procedures

Procedures for cleaning, checking connections, and general upkeep of the welding machine.

Welder Troubleshooting Guide

General Troubleshooting Guide

Common issues, causes, and solutions for the welding machine.

MMA and MIG;MAG Troubleshooting

Specific troubleshooting for MMA and MIG/MAG welding issues.

Welder Wiring Diagram

Wiring Diagram Reference

Reference to the machine's internal wiring diagram provided in the appendix.

About This Welder Manual

Manual Scope and Updates

Information on manual applicability to models and potential updates.

Jasic MIG 350P Specifications

General IconGeneral
Output Current Range50-350 A
Duty Cycle60% at 350 A
Protection ClassIP21S
Insulation ClassF
Efficiency85%
Power Factor0.93
Input Voltage3 Phase 400V
Wire Diameter0.8-1.2 mm
Wire Feed Speed1.5 - 18 m/min

Related product manuals