OPERATOR’S MANUAL · MIG/MAG PULSE SERIES
- 20 -
LF base value running.
6.6 Operation mode selecting
For MIG/MAG operation modes, see Table 6.6.1 for reference; for torch trigger operation notes, see Table 6.6.2 for
reference.
Table 6.6.1 MIG/MAG operation modes
Mode no. Operation Gun trigger operation and current curve
1T/Spot welding mode:
① Push the torch trigger: arc is ignited and current
rises to the preset value.
② When the spot welding time is up, current drops
gradually, and arc stops.
Standard 2T mode:
① Push the torch trigger: arc is ignited and current
rises to the initial value, then gradually rises or
drops to the preset value.
② Release the torch trigger: current drops gradually,
and arc stops.
4T mode:
① Push the torch trigger: arc is ignited and current
rises to the initial value, then rises or drops
gradually. The torch trigger can be released at any
time.
② Push it again: current gradually drops to crater
current value.
③ Release it: arc stops.
Programmed 4T mode:
① Push the torch trigger: arc is ignited and current
reaches the initial value.
② Release it: current rises gradually.
③ Push it again: current drops to crater current value.
④ Release it: arc stops.
Table 6.6.2 Torch trigger operation notes
Push the torch trigger.
Release the torch trigger.
Push the torch trigger and then release it at any time.
Release the torch trigger and then push it at any time.