6
For example, if the duty cycle is 60%, the load-applying time shall be 6 minutes and the following.
3.2 Output characteristics
4. INSTALLATION
4.1 Installation requirements
4.1.1 Working environment
Please pay attention to the following items when choosing the installation environment
Avoid installation in places filled with dusts or metal powder.
Avoid installation in places filled with corrosive and explosive gases.
Please make sure the working environment is within 10~+40; extra forced heat dissipation or derating
operation is required if the temperature is more than 40
Humidity has to be below 90 and of no condensed water drop
Make sure there is no wind in the welding site; please use wind screen if necessary, or else the welding
performances may be affected.
Please consult and confirm with Jasic qualified personnel first if there is any special installation requirements.
4.1.2 Installation space requirements
Keep the welder more than 30cm distant from the wall or any other equipment.
U(V)
86
40
20
14
I(A)
U
2
=14+0.05I
2
U(V)
55
20
10
I(A)
MMAU
2
=20+0.04I
2
TIGU
2
=10+0.04I
2
500
MIG is of CV characteristics
Output external characteristics
curve is as shown on the right.
MMA & Lift-TIG are of CC
characteristics.
Output external characteristics
curve is as shown on the right.