CONFIGURATION AND CALIBRATION –Software Config.
Page 58 of 80
Rudder Feedback Tuning Window
The Rudder Feedback Tuning
Window contains the
Proportional, Integral and
Derivative values for the
feedback loop. These values
are derived through a tuning
process and adjustment of these
values is normally not required.
CAUTION:
The Proportional, Integral and Derivative terms on this Property Sheet
should only be adjusted by someone familiar with the tuning process of a
PID controller and the desired response of a proportional steering control
system.
System Configuration Window
The System Configuration
Window consists of three
different Window Tabs.
Under the System
Configuration Tab settings
are adjusted for the system
voltage (12 or 24 volts),
rudder angle, solenoid type
(on-off or proportional),
synchronized system (on or
off) and dual speed control
(on or off).