www.procontechnology.com.au Phone: (03) 98306288
SPECIFICATIONS
Technical Specifications:
Insulation: Class2, Double insulation.
Overvoltage category: CATIV 600V, CAT III 1000V
NOTE: This meter meets CAT III and CAT IV IEC 61010
standards. The IEC 61010 safety standard defines four
overvoltage categories (CAT I to IV) based on the magnitude of
danger from transient impulses. CAT III meters are designed to
protect against transients in fixed-equipment installations at the
distribution level; CAT IV meters are designed to protect
against transients from the primary supply level (overhead or
underground utility service).
Maximum voltage between any terminal and earth ground:
1000V DC/AC RMS
Display: 4000 counts LCD display
Polarity: Automatic, (-) negative polarity indication.
Over-range: "OL" indication.
AC Response: True RMS
Low battery indication: A battery " " symbol is displayed
when the battery voltage drops below the operating level.
Auto power off: Meter automatically shuts down after
approx. 30 minutes of inactivity unless in wireless mode.