STEP 6
:
Attach 2nd J-Link
n After pulling the rst culvert, you may need to attach the 2nd J-Link
to keep one culvert between the puller and the culvert being pulled,
as shown in the picture below.
n After the rst culvert is seated, release it by activating the remote.
n Switch the Valve Selector to the left, and support the strut with your hand.
Activate the remote- this will un-wedge the strut.
n Reposition the puller and extend the pulling cylinder so after you add
the 2nd J-Link, it drops over the J-Hook as you retract the pulling cylinder.
STEP 7
:
Release Pipepuller and Reposition
n After the culvert is seated, release the culvert by activating the remote.
n Switch the Valve Selector to the left, and support the strut with your hand.
Activate the remote- this will un-wedge the strut.
n With the strut cylinder completely retracted, the JB Pipepuller is ready
to move forward. Repeat steps 5 & 6 until all culverts are set.
Operation l JB Pipepuller
18
OPERATION Continued