5. Select Test In the Test menu, select one of the following:
For Layer 2 Electrical (Copper/RF-45) Testing:
Ethernet>10/100/1000>Layer 2 Traffic> Terminate.
For Layer 2 Optical Testing:
Ethernet>1GigE Optical>Layer 2 Traffic> Terminate.
For Layer 3 IPv4 Electrical Testing:
Ethernet>10/100/1000>Layer 3 Traffic> IPv4>Terminate.
For Layer 3 IPv4 Optical Testing:
Ethernet>1GigE Optical>Layer 3 Traffic> IPv4>Terminate.
6. Reset to Defaults In the Tools menu, select Reset Test to Defaults. Press OK to continue.
7. Setup Press the SETUP soft key on the top right side of screen. Select the
indicated folders and configure your test as follows. Leave all other
values at default, unless specified in the Work Order.
Folder
Option
Value(s)
Comment
Interface,
Physical
Layer
Auto
Negotiation
See Work Order Set to same value as Ethernet switch port.
Duplex
See Work Order
Options only displayed if Auto Negotiate
= Off
Speed
For Layer 3 IPv4 testing, configure the following additional settings:
Folder
Option
Value(s)
Comment
IP
Source IP Type
Static
Options displayed after tapping
Source/Destination Addresses field.
Source IP
See Work Order
Default Gateway
See Work Order
Subnet Mask
See Work Order
Destination IP See Work Order
If unknown, enter IP Address of
Default Gateway
8. View Results Press the RESULTS soft key, to display the Results screen.
9. Turn Laser On If testing an Optical link, select the Laser tab in the lower part of the
screen and press Laser Off. The button will turn Yellow and be
relabeled to indicate the Laser is On.