Page 21 of 24
10. Setup Press the SETUP soft key on the top right side of screen. Select the
indicated folders and configure your test as follows. Leave all other
values at default, unless specified in the Work Order.
Interface,
Connector
Electrical
Connector
SFP1 or SFP2
For Electrical tests, select
ETHERNET 1000BASE-T SFP
Interface,
Connector
Optical
Connector
SFP1 or SFP2
For Optical tests, select desired optical
SFP (1000BASE-SX, 1000BASE-LX,
Interface,
Physical
Layer
See Work Order Set to same value as Ethernet switch port.
See Work Order
Options only displayed if Auto Negotiate
= Off
For Layer 3 IPv4 testing, configure the following additional settings:
IP
Options displayed after tapping
Source/Destination Addresses field.
Destination IP See Work Order
If unknown, enter IP Address of
Default Gateway
11. View Results Press the RESULTS button, to display the Results screen.
12. Turn Laser On If testing an Optical link, select the Laser tab in the lower part of the
screen and press Laser Off. The button will turn Yellow and be
relabeled to indicate the Laser is On.
13. Check LEDs Press the Restart soft key on the Right side of the display to reset test
results. A Green Signal Present LED indicates that the T-BERD is
receiving an optical signal from the near end Ethernet Switch. Green
Sync Acquired and Link Active LEDs indicate that the T-BERD has
successfully connected to the near end Ethernet switch and the Ethernet
link is active.
14. Check AutoNeg Stats For Copper (RJ-45) connections, if Auto Negotiation was enabled in the
Interface Setup, Set the right Results Group/Category to
Ethernet/Autoneg Status. Verify that Link Config ACK = Yes and
Duplex = Full.
Technical Support tac@jdsu.com 855-275-5378