11. Check AutoNeg Stats For Electric connections, if Auto Negotiation was enabled in the Link
Init Setup, press the Right Arrow key until Auto-Neg Results are
displayed. Verify that Link Config ACK = Yes and Duplex = Full.
12. Check LED Results Press the Right Arrow key until LED Results are displayed. A Green
Signal Present LED indicates that the HST-3000 is receiving an optical
signal from the near end Ethernet Switch. Green Sync Acquired and
Link Active LEDs indicate that the HST-3000 has successfully
connected to the near end Ethernet switch and the Ethernet link is active.
13. Check ARP Status If you are running a Layer 3 IPv4 Test, verify that the final message in
the Message bar is “ARP Done
If “ARP Done” is not displayed, verify that the HST-3000’s IP menu is
configured correctly, as outlined above.
14. Run Test Press the Action soft key and select Start RFC 2544. The HST-3000
will loop up the far end unit, and test Throughput, Delay, Jitter, and
Frame Loss. The test will take about 7 minutes to complete. At the
conclusion of the test, the HST-3000 will automatically loop down the
far end JDSU loopback device and create a test report in PDF format.