EasyManua.ls Logo

Jeep 2002 WJ - Operation

Jeep 2002 WJ
291 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Regulating Valve Pressure Regulating Valve
The regulating valve pressure regulating valve
(Fig. 72) is located in the valve housing of the elec-
trohydraulic control module. It regulates the regulat-
ing valve pressure (p-RV).
Shift Valve Pressure Regulating Valve
The shift valve pressure regulating valve (Fig. 73)
is located in the valve housing of the electrohydraulic
control module. It regulates the shift valve pressure
(p-SV).
OPERATION
ELECTRICAL CONTROL UNIT
Signals from the transmission control module
(TCM) are converted into hydraulic functions in the
electric valve control unit (7) (Fig. 74). The RPM sen-
sors (1, 12), starter interlock contact (9), and trans-
mission oil temperature sensor (8) of the electric
valve control unit (7) supply the TCM with input sig-
nals. The solenoid valves are controlled by the TCM
and trigger the hydraulic functions.
Fig. 72 Regulating Valve Pressure Regulating Valve
1 - REGULATING VALVE PRESSURE REGULATING VALVE
Fig. 73 Shift Valve Pressure Regulating Valve
1 - SHIFT VALVE PRESSURE REGULATING VALVE
Fig. 74 Electrical Control Unit
1 - N3 SPEED SENSOR
2 - PLUG CONNECTOR
3 - MODULATING PRESSURE REGULATING SOLENOID
4 - SHIFT PRESSURE REGULATING SOLENOID
5 - 1-2/4-5 SHIFT SOLENOID
6 - 3-4 SHIFT SOLENOID
7 - ELECTRICAL CONTROL UNIT
8 - TRANSMISSION TEMPERATURE SENSOR
9 - STARTER INTERLOCK CONTACT
10 - 2-3 SHIFT SOLENOID
11 - TORQUE CONVERTER LOCK-UP SOLENOID
12 - N2 SPEED SENSOR
21a - 62 TRANSMISSION AND TRANSFER CASE WG
ELECTROHYDRAULIC UNIT (Continued)

Table of Contents