5.4 Output Configuration
TYPE
SOT (Set Output Type) parameter 16 Bit
2 Bit-value per output
Output
8
7
6
5
4
3
2
1
SOT Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Bit- value
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Decimal
21845
*Default setting all output on SOURCE
>SOT 21845
ACTIVITY
SOA (Set Output Activity) parameter 8 Bit
1 Bit-value per output
Output
8
7
6
5
4
3
2
1
SOA Bit
7
6
5
4
3
2
1
0
Bit-value
1
1
1
1
1
1
1
1
Decimal
255
*Default setting all output HIGH ACTIVE
>SOA 255
Parameter Values
Output
SOT
Bit
SOT
Bit-value
TYPE
SOA
Bit
SOA
Bit-value
ACTIVITY
Output
ON
Output
OFF
1
0,1
0,0
SINK
0
0
HIGH
0V
open
0
1
LOW
open
0V
2
2,3
0,1
SOURCE
1
0
LOW
open
24V
1
1
HIGH
24V*
open*
3
4,5
1,0
SINK/SOURCE
2
0
LOW
0V
24V
2
1
HIGH
24V
0V
Examples
Output
SOT
Bit
SOT
Bit-value
TYPE
SOA
Bit
SOA
Bit-value
ACTIVITY
Output
ON
Output
OFF
1
0,1
0,0
SINK
0
0
HIGH
0V
open
2
2,3
0,1
SOURCE
1
1
HIGH
24V*
open*
3
4,5
0,1
SOURCE
2
1
HIGH
24V*
open*
4
6,7
0,1
SOURCE
3
1
HIGH
24V*
open*
5
8,9
1,0
SINK/SOURCE
4
0
LOW
0V
24V
6
10,11
1,0
SINK/SOURCE
5
0
LOW
0V
24V
7
12,13
1,0
SINK/SOURCE
6
1
HIGH
24V
0V
8
14,15
0,0
SINK
7
1
HIGH
0V
open
SOA
11001110
b
206
d
SOT
0010101001010100
b
10836
d