MAINTENANCE AND FAULT FINDING PROCEDURES
WARNING: ALWAYS ISOLATE UNIT FROM THE ELECTRICAL SUPPLY BEFORE ATTEMPTING ANY REPAIRS OR
MAINTENANCE.
TROUBLESHOOTING GUIDE
FAULT CAUSE
AUTOMATIC MODELS MANUAL MODELS
A The motor does not start 1-2-3-4-5-7-17-18 1-2-3-5-7
B The heater stops and the lockout light (11) comes on 6-8-9-10-17
C The fan turns but the heater cannot be ignited 11-17-18 8-9-10-11-13-17-18
D The flame stops after letting go of the gas relay valve knob (22) 10-13-14-17
E Gas flow is interrupted. The flame extinguishes 10-11-17 10-11-17
F The heater consumes too much gas 15-16 15-16
G The heater stops completely 4-12 12
FAULT CORRECTION
THE MANUFACTURER RECOMMENDS THAT ALL REPAIRS AND MAINTENANCE WORK BE CARRIED OUT BY A QUALIFIED TECHNICIAN.
CAUSE
1. Electricity Supply is faulty
Check the power plug is plugged in.
Check that electricity supply is available
2. The motor is blocked/faulty
Check and replace as necessary
3. The fan is blocked/damaged
Check and replace as necessary
4. IF FITTED (AUTOMATIC ONLY)
The thermostat setting is incorrect
The thermostat plug is not plugged in
The thermostat/thermostat connection is loose/faulty
Adjust thermostat accordingly
Plug the thermostat plug into the appropriate socket
Check and replace as necessary
5. Switch/switch connections is/are faulty/loose
Check and replace as necessary
6. Power Socket/Extension cord/plug incorrectly wired (Phase
indicator light (73) is on)
Rewire plug/extension cord/power socket if necessary and
check that phase indicator light is off
7. Limit thermostat is faulty
Reset Limit thermostat (WHERE FITTED)
Check for continuity in Limit thermostat connection
8. Gas pressure/flow absent before solenoid valve
Check that the gas supply is on at the cylinder
Check that the gas cylinder(s) is/are full and not ‘frozen’
Check that the gas cock is in the open position and operating
correctly
9. Solenoid valve does not open
Check the solenoid valve and its connection
Adjust or replace as necessary
Check the Limit thermostat
10. Flame detecting probe and/or ignition electrode are not adjusted
or working properly
Check and adjust or replace as necessary
11. Inlet/outlet grill or inside of heater is dirty or partially blocked
Check and clean as necessary
12. Limit thermostat cuts in interrupting the heater
Reset Limit thermostat (WHERE FITTED)
Check if the inlet/outlet grill are dirty or blocked, clean as
necessary
Check that airflow in and out of the heater is not impeded
13. Gas relay valve/thermocouple is faulty
Check and replace as necessary (Make sure when starting that
the Gas relay valve button is kept pressed for 30 seconds after
ignition)
14. Thermocouple is not properly adjusted
Check thermocouple positioning and adjust accordingly
15. Pressure regulator is faulty
Check and replace as necessary
16. There is a leak in the gas delivery line
Immediately close gas supply at bottle. Check hose and
unions in the delivery line are tight (Use a soap solution to
locate leaks – NEVER USE A NAKED FLAME)
17. Control box faulty
Check and replace as necessary
18. Air Proving switch (28) is faulty (WHERE FITTED)
Check and replace as necessary