Summary

Introduction and General Description

Introduction

Overview of Spitwater, Jetfire heaters, and the purpose of this manual.

General Description & Intended Use

Applications for heating, drying, and desiccating in commercial and industrial settings.

Technical Specifications

Technical Specification

Detailed technical data including power, voltage, current, dimensions, and weight for different models.

Safety Information and Symbols

Description of Symbols

Explanation of various warning and informational symbols used in the manual.

Important Safety Instructions and Precautions

Critical warnings and guidelines for safe operation to prevent injury or death.

Safety Labels

Advice on paying attention to and not removing safety labels on the unit.

General Advice and Safety Guidelines

Important Safety Instructions and Precautions (Continued)

Further general safety guidelines for operation, placement, and user supervision.

General Advice

Installation, setup, and usage in accordance with regulations and minimum distance requirements.

Electrical Connection

Guidelines for connecting the unit to the power supply, including voltage, phase, and safety devices.

Power Cord

Instructions for checking and handling the power cord to prevent damage and ensure safety.

Extension Cord

Requirements for using extension cords, including length, sizing, and proper handling.

Trip Hazard

Warnings about trip hazards from loose cords and safety measures to mitigate them.

Fire Prevention and Hot Surface Caution

Precautions regarding flammable materials, clearances, and hot surfaces to prevent fires and burns.

Exhaust & Flue Gases

Safety considerations for exhaust fumes, carbon monoxide, ventilation, and minimum room size.

Fuel and Lubricants

Warning about smoking or sparks in the work area due to flammable fuel.

Transport

Instructions for safely disconnecting, lifting, and moving the unit.

Maintenance and Service

Guidelines for checking safety, performing maintenance, using spare parts, and service agent requirements.

Control Board and Operation

Control Board Overview

Identification and function of controls on the 3kW, 10kW, 15kW, 22kW, and 30kW models.

Installation Instructions

Requirements for installation by skilled personnel, power supply checks, earth lead, RCD, plug/socket connection.

Operating Instructions (Mod. 3 kW)

Steps to start and operate the 3 kW model, including power selection and temperature setting.

Operating Instructions (Mod. 10;15;22;30 kW)

Steps for heating mode, shutdown, and ventilation mode for higher kW models.

Safety Thermostat Manual Reset

Procedure to reset the temperature-limit thermostat after overheating.

Cleaning

Importance and frequency of cleaning for efficient operation and fire prevention.

Disposal

Guidelines for environmentally responsible disposal of the product at its end of life.

Observed Faults, Possible Causes and Remedies

Troubleshooting guide for common issues, their causes, and recommended solutions.

Assembly Instructions

Foot; Handle Assembly Instruction

Instructions and parts list for assembling feet and handles on 3kW and 10/15/22kW models.

Foot; Handle Assembly Instruction (30 kW)

Instructions and parts list for assembling feet and handles on the 30kW model.

Overview

This document is an operating and maintenance manual for JETFIRE Electric Space Heaters, specifically models E3, E10, E15, E22, and E30. These heaters are designed for industrial use and space heating only, not for domestic use. They are manufactured in Italy for Spitwater Australia Pty Ltd T/A Ottico Equipment.

Function Description

JETFIRE heaters are portable industrial electric space heaters designed for heating, drying, and desiccating in commercial and industrial applications such as warehouses, factories, animal husbandry, and greenhouses. They operate by drawing air from the environment with a fan, heating it using armour-plated resistance, and then releasing the heated air back into the environment. The units are constructed from steel sheets with a double wall to enhance efficiency and limit external wall temperatures. They are designed for floor use only.

Important Technical Specifications

The manual provides a detailed technical specification table for each model:

  • Heat Power:
    • E3: 3 kW
    • E10: 10 kW
    • E15: 15 kW
    • E22: 22 kW
    • E30: 30 kW
  • Phase:
    • E3: 1 Phase
    • E10, E15, E22, E30: 3 Phase
  • Voltage:
    • E3: 230 V
    • E10, E15, E22, E30: 400 V
  • Frequency:
    • E3, E10, E15, E22: 50 Hz
    • E30: 60 Hz
  • Control Options (kW):
    • E3: 1.5 / 3.0
    • E10: 6.66 / 10.0
    • E15: 10.0 / 15.0
    • E22: 14.7 / 22.0
    • E30: 20.0 / 30.0
  • Electric Current (A) MAX:
    • E3: 13.0
    • E10: 13.5
    • E15: 21.0
    • E22: 30.0
    • E30: 43.0 (at 50Hz) / 43.0 (at 60Hz)
  • Air Flow Rate (m³/h):
    • E3: 450
    • E10: 1500
    • E15: 2000
    • E22: 3050
    • E30: 5100 (at 50Hz) / 6500 (at 60Hz)
  • Electrical Protection Level: IPX4 for all models.
  • Noise Level at 1 m (dBA):
    • E3: 67
    • E10: 68
    • E15: 70
    • E22: 71
    • E30: 69
  • Dimensions (L x W x H in mm):
    • E3: 367x180x280
    • E10: 505x277x511
    • E15: 575x277x511
    • E22: 700x317x538
    • E30: 899x558x706
  • Weight (kg):
    • E3: 5
    • E10: 13
    • E15: 15
    • E22: 21
    • E30: 41

Usage Features

The heaters are equipped with a control board that includes:

  • Room Thermostat (1): To set the desired temperature.
  • Overheating Thermostat Manual Reset (2): A safety feature that stops power in case of overheating.
  • Main Switch (3): For turning the unit on/off and selecting operating modes.
  • Power Switch (4): To select electric power output (minimum or maximum heating).
  • Lamp (5): Indicates operation.
  • Room Thermostat Plug (6) (for Mod. 30 kW): Allows connection to an external room thermostat or timer.

Operating Instructions (Mod. 3 kW):

  1. Start: Press the main switch (3) to start the fan immediately. Turn the room thermostat knob (1) to the desired temperature to activate the electric heaters.
  2. Power Selection: Use the power switch (4) to select minimum or maximum heating.
  3. Shutdown: Turn the room thermostat knob (1) to the minimum temperature to turn off heating elements while the fan continues. Press the main switch (3) to stop the fan.

Operating Instructions (Mod. 10 kW / 15 kW / 22 kW / 30 kW):

  1. Heating Mode Start: Turn the main switch knob (3) to position 'a' for minimum power or 'b' for maximum power. The fan starts immediately, and heating elements heat up gradually. Turn the room thermostat knob (1) to the desired temperature; the electric heaters will run until the set temperature is reached, and the lamp (5) will light up.
  2. Heating Mode Shutdown: Turn the room thermostat knob (1) to the minimum temperature to shut down heating elements while the fan continues. Turn the main switch knob (3) to position 'd' for complete shutdown; the fan runs until heating elements have cooled down sufficiently, then stops. These models feature an automatic power-off cooling ventilation function.
  3. Ventilation Mode (without heating) Start: Turn the main switch knob (3) to position 'c'.
  4. Ventilation Mode Shutdown: Turn the main switch knob (3) to position 'd'.

Safety Precautions:

  • Heaters must be operated by authorized persons in a well-ventilated space.
  • Not for domestic use; only for industrial space heating.
  • Do not spray aerosols, use, or store flammable materials near the appliance.
  • Do not modify the appliance or place articles on it.
  • Operate on flat, stable ground, in an upright position, and protected from elements.
  • Never leave unattended.
  • Keep children and animals away.
  • Minimum clearance: 3m in front (air outlet), 1m above and behind (air inlet), and 600mm on the sides.
  • Exhaust fumes contain carbon monoxide; ensure permanent ventilation to the outside atmosphere. Mandatory minimum room size: 350 m³.
  • For 30 kW models, check fan rotation direction on first use and reverse phases if necessary.
  • Electrical connections must be made by certified electricians, adhering to local regulations.
  • Recommended to include a residual current device (RCD) with a 30mA trip for 30ms.
  • Class 1 Appliance must be earthed.
  • Power cords and extension cords must be undamaged, correctly sized (e.g., <10A: 1.5mm², <15A: 2.5mm², <25A: 4.0mm²), and kept dry, unrolled, and away from traffic/heat.
  • Keep combustible materials a minimum of 3m away from the unit. An external guard should be placed 1m from the heater outlet.
  • Firefighting equipment should be readily available.
  • Be cautious of hot components.

Maintenance Features

  • Regular Inspection: The heater must be checked for safety and proper working order before every use.
  • Daily Inspection: Follow the "Daily inspection check list" guide (Table-B in the Maintenance section, though not provided in this excerpt).
  • Service Frequency: Service the unit regularly based on usage, following the "Usage vs Service frequency" Table (Table-A in the Maintenance section, also not provided).
  • Authorized Service: All servicing, including checking and setting safety devices and combustion, must be carried out by a Spitwater authorized service agent.
  • Spare Parts: Always use original Spitwater spare parts.
  • Before Maintenance: Always disconnect the unit from the power supply, allow it to cool, and turn off the disconnecting switch on the electric switchboard.
  • No Modifications: Never carry out maintenance work not expressly outlined in the manual or make modifications to the unit.
  • Cleaning: Regular cleaning is essential for efficient operation, as dust and dirt can cause overheating and fire.
  • Troubleshooting: The manual includes a table for observed faults, possible causes, and remedies, such as:
    • Fan doesn't start: Check electrical current, switch positioning, or replace motor.
    • Fan starts but not enough heat: Check room thermostat setting or replace it.
    • Space heaters stop: Identify and fix the problem causing the safety thermostat to intervene.
  • Disposal: At the end of its useful life, the product must be disposed of at a local differentiated waste collection center in conformity with law (Italian legislative decree 151 of 25/07/2005 and directive 2002/96/ec on waste electrical and electronic equipment).

Jetfire E3 Specifications

General IconGeneral
BrandJetfire
ModelE3
CategoryHeater
LanguageEnglish