37
SECTION VII
REVERSING TIMER SPIN/DWELL ADJUSTMENTS
(OPL DUAL TIMER MODELS ONLY)
Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left
rear area of the dryer.
Both the dwell (stop) time and the basket (tumbler) spin time are adjustable by mode selection switches located
on the electronic timer (refer to the illustration below).
TIMING LEGEND
SPIN TIME
Adjustment Position Number 1 2 3 4 5
Time in Seconds* 30 60 90 120 150
DWELL (STOP) TIME
Adjustment Position Number 1 2 3 4 5
Time in Seconds* 5 6.3 7.6 8.9 10.2
* Values shown are +/- 1-second.