EasyManua.ls Logo

JLA /T75 - Gas Consumption and Orifice Data; Non-CE Dryer Gas Data; CE Dryer Gas Data

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22 JLA Limited 113429-9
Heat Input/Gas Consumption/Orifice (Injector) Data (For Non CE [European] Models Only)
Shaded areas are stated in metric equivalents
* Gas valve’s internal regulator disabled.
** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Shaded areas are stated in metric equivalents
* Gas valve’s internal regulator disabled.
** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)
Gas Specifications for CE Approved Dryers**
Model
Gas
Type
Nominal
Heating Value
Supply
Pressure
Gross
Heat Input
Fuel
Consumption
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
Btu/ft
3
mb Btu/hr kW DMS mm mb
T20
Natural (I
2H
/I
2E
)1,000
15-30
40,000
11.72 1.133 M
3
/H
30
3.264
1
6.7
Natural (I
2L
)830
20-35
40,000
11.72 1.365 M
3
/H
30
3.264
1
9.2
Natural (I
2ELL
)830
15-30
40,000
11.72 1.365 M
3
/H
30
3.264
1
9.2
*Natural (I
2E+
)
1,000
20
40,000
11.72 1.133 M
3
/H
38
2.578
1
830
25
40,000
11.72 1.365 M
3
/H
38
2.578
1
*Butane (I
3+
)3,175
28-30
40,000
11.72 0.845 kg/H
52
1.613
1
*Propane (I
3+
)2,500
37
40,000
11.72 0.845 kg/H
52
1.613
1
Butane (I
3B/P
)3,175
28-30/50
40,000
11.72 0.845 kg/H
49
1.854
1
18.0
Propane (I
3P
)2,500
28-30/50
40,000
11.72 0.845 kg/H
49
1.854
1
23.0
T30
Natural (I
2H
/I
2E
)1,000
15-30
55,000
16.12 1.557 M
3
/H
22
3.988
1
6.9
Natural (I
2L
)830
20-35
55,000
16.12 1.876 M
3
/H
22
3.988
1
9.5
Natural (I
2ELL
)830
15-30
55,000
16.12 1.876 M
3
/H
22
3.988
1
9.5
*Natural (I
2E+
)
1,000
20
55,000
16.12 1.557 M
3
/H
31
3.048
1
830
25
55,000
16.12 1.876 M
3
/H
31
3.048
1
*Butane (I
3+
)3,175
28-30
55,000
16.12 1.162 kg/H
48
1.930
1
*Propane (I
3+
)2,500
37
55,000
16.12 1.162 kg/H
48
1.930
1
Butane (I
3B/P
)3,175
28-30/50
55,000
16.12 1.162 kg/H
44
2.184
1
18.1
Propane (I
3P
)2,500
28-30/50
55,000
16.12 1.162 kg/H
44
2.184
1
24.9
T50
Natural (I
2H
/I
2E
)1,000
15-30
90,000
26.38 2.549 M
3
/H
29
3.454
2
7.2
Natural (I
2L
)830
20-35
90,000
26.38 3.071 M
3
/H
29
3.454
2
8.9
Natural (I
2ELL
)830
15-30
90,000
26.38 3.071 M
3
/H
29
3.454
2
8.9
*Natural (I
2E+
)
1,000
20
90,000
26.38 2.549 M
3
/H
35
2.794
2
830
25
90,000
26.38 3.071 M
3
/H
35
2.794
2
*Butane (I
3+
)3,175
28-30
90,000
26.38 1.901 kg/H
50
1.778
2
*Propane (I
3+
)2,500
37
90,000
26.38 1.901 kg/H
50
1.778
2
Butane (I
3B/P
)3,175
28-30/50
90,000
26.38 1.901 kg/H
47
1.994
2
18.1
Propane (I
3P
)2,500
28-30/50
90,000
26.38 1.901 kg/H
47
1.994
2
24.9
T75
Natural (I
2H
/I
2E
)1,000
15-30
110,000
32.24 3.115 M
3
/H
22
3.988
2
6.9
Natural (I
2L
)830
20-35
110,000
32.24 3.753 M
3
/H
22
3.988
2
9.5
Natural (I
2ELL
)830
15-30
110,000
32.24 3.753 M
3
/H
22
3.988
2
9.5
*Natural (I
2E+
)
1,000
20
110,000
32.24 3.115 M
3
/H
31
3.048
2
830
25
110,000
32.24 3.753 M
3
/H
31
3.048
2
*Butane (I
3+
)3,175
28-30
110,000
32.24 2.324 kg/H
48
1.930
2
*Propane (I
3+
)2,500
37
110,000
32.24 2.324 kg/H
48
1.930
2
Butane (I
3B/P
)3,175
28-30/50
110,000
32.24 2.324 kg/H
44
2.184
2
18.1
Propane (I
3P
)2,500
28-30/50
110,000
32.24 2.324 kg/H
44
2.184
2
24.9
Gas Specifications for Non-CE Approved Dryers**
Model
Gas
Type
Nominal
Heating Value
Supply
Pressure
Gross
Heat Input
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
Btu/ft
3
in wc Btu/hr kW DMS mm in wc
T20
Natural 1,000
7.0-13.0
40,000
11.72
30
3.264
1
3.0
*Liquid Propane 2,500
11.0
40,000
11.72
49
1.854
1
10.0
T30
Natural 1,000
7.0-13.0
55,000
16.12
20
4.089
1
3.0
*Liquid Propane 2,500
11.0
55,000
16.12
44
2.184
1
10.0
T50
Natural 1,000
7.0-13.0
90,000
26.38
29
3.454
2
3.0
*Liquid Propane 2,500
11.0
90,000
26.38
47
2.994
2
10.0
T75
Natural 1,000
7.0-13.0
110,000
32.24
22
3.988
2
3.0
*Liquid Propane 2,500
11.0
110,000
32.24
44
2.184
2
10.0

Related product manuals