  • R
    Ronald RamirezAug 13, 2025
    What to do if my JLG Lifting Systems unit is off and the engine won't crank?
    • L
      lawrenceadamsAug 13, 2025
      If the JLG Lifting Systems unit is off or disabled, and the engine won't crank, begin by checking the position of the selector switch and ensure the inhibit run is released. Inspect the warning LED and address any faults before restarting the RBS. Verify the start battery voltage, check the control fuse, and look for any loose wiring or connections.
  • C
    Connor HowardAug 17, 2025
    Why is my JLG Lifting Systems engine temperature high?
    • E
      Emily MccannAug 17, 2025
      If your JLG Lifting Systems engine temperature is high, check for any obstructions blocking the cooling airflow to the engine. Ensure the ambient temperature is within the engine's design limits. Also, verify the correct operation of the engine temperature sensor.
  • A
    Amanda HicksAug 21, 2025
    What to do if my JLG Lifting Systems engine is overcranking?
    • D
      Danielle BellAug 21, 2025
      If the JLG Lifting Systems engine is experiencing an overcrank, first check the fuel level and connections. Then, verify the operation of the fuel solenoid and fuel pump. Check the start battery voltage. If the engine exhaust contains white smoke, it indicates fuel is entering the engine but the engine is not firing. If the ambient temperature is low, verify that the heater and/or glow plug are operating.
  • R
    rebeccaandersonAug 25, 2025
    Why is my JLG Lifting Systems engine running with underspeed?
    • T
      Tanya BoyerAug 25, 2025
      If the JLG Lifting Systems engine is running with underspeed, make sure there's enough fuel and combustion air going to the engine. Check the air cleaner. Also, check the governor lever setting and readjust it if needed.
  • L
    Lee MccormickAug 28, 2025
    What to do if my JLG Lifting Systems shows low oil pressure?
    • P
      Patrick ReevesAug 28, 2025
      If the JLG Lifting Systems reports low oil pressure, check the oil level and the oil supply lines. Also, verify the correct operation of the oil pressure switch with a test gauge.
  • J
    Jessica BrownSep 1, 2025
    What causes overspeed in JLG Lifting Systems?
    • H
      Heather TravisSep 1, 2025
      If the JLG Lifting Systems indicates an overspeed condition, verify the setting of the governor lever and readjust it if required.
  • A
    amywalkerSep 5, 2025
    What to do if my JLG Lifting Systems shows overvoltage?
    • J
      jonespennySep 5, 2025
      If the JLG Lifting Systems shows an overvoltage, check the alternator output voltage.
  • M
    Michelle EdwardsSep 8, 2025
    What to do if my JLG Lifting Systems has no speed signal?
    • B
      Brittany JimenezSep 8, 2025
      If the JLG Lifting Systems has no speed signal, check the wiring connections.