Characteristics:
Sizes:
72” / 1830 mm
high
31,62” / 803mm
wide
36,81” / 930mm
deep
Weight
: 705 Lb / 315 Kg
Electrics:
Power supply: 220-240 VAC. 0r 110 VAC
Verify the ground connection is proper before
turning on the machine
Capacity:
Up to 8 trays with 7 motors each.
Cooling Unit
(Only ComboPlus Machine
and in Multiplus if requested):
R-134A Ecological gas
To nd out the amount of gas, read it on
the compressor’s sticker.
If the machine has cooling unit leave
a space between the wall and the
back of the machineof
7” / 20cm
Coin changer
J-2000 with 5 tubes
Currency validator
, Jofemar BT10
If you need more capacity or diversity on
your sales point chech with you Jofemar
agent about the possibilitie of an Extra
Selections Unit
72”
1830 mm
36,81”
935 mm
935 mm
31,62”
803 mm
WARNING! safety instructions
Read the following instructions carefully before installing the unit:
Take the machine down from the pallet and remove the metal chucks to place it on the oor before opening and removing
the packaging.
◊ When discarding packaging material or an old machine, please consult about recycling.
Before connecting to mains, make sure that the power supply characteristics coincide with those of the machine.
◊ The power cable plug should be installed so the machine can be easily disconnected from mains.
If the power cable is damaged, it should be replaced by the manufacturer or after sales service or similar
quali ed personnel to prevent hazards.
◊ Place a rubber protection around the power cable in the slot of the lid of the cable winding recess.
Do not burn or throw away the battery. Batteries should be disposed of in accordance with local laws and
regulations and can be recycled.
Protect the machine against humidity, dust, dirt, etc. You should particularly avoid any obstruction of the
ventilation grilles.
◊ Do not clean the machine with concentrated products as they may attack the paint and alter the colour.
◊ Frequent cleaning, can prevent breakdowns and extend the machine’s life.
The machine should be installed in a vertical position, both laterally and back to front, with a maximum
inclination of 5% (~2°).
If you need to replace the power supply cable, please replace it with the appropriate one for your country:
Argentina, Jofemar code 5500014. Australia, Jofemar code 5500006. Spain (STANDARD), Jofemar code
5500000. UK, Jofemar code 5500011. Switzerland, Jofemar code 5500004. USA, Jofemar code 5500010.