LP69910 (12/07/2020) 3 CU FT GATOR FERTILIZER SPREADER
Operation
Display Screen Messages
During operation a message may appear describing a
potential issue or problem.
Motor Over Current A motor is drawing too
much current. Spreader will
shut down, display an error
message, and prompt the
operator to reset the spreader.
The spinner disk may be
jammed and needs to be
cleared.
Motor Open Circuit This message is displayed
when a motor is disconnected.
Ensure that all harnesses
are installed correctly, and
connectors are fully seated.
Ensure that the status light on
the motor controller is green.
Voltage High This message is displayed
when the controller is receiving
a voltage higher than 16V.
Please check battery voltage.
Voltage low This message is displayed
when the controller is receiving
a voltage lower than 9V. Please
check battery voltage.
No Comm This message is displayed
when there is a loss of
communication with the
motor controller. Ensure that
all harnesses are installed
correctly, and connectors
are fully seated. Ensure that
the status light on the motor
controller is green.