SYSTEM TESTS
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF 133 178
PANEL GLASS BREAK DETECTION REQUIREMENTS
Panel Installation Requirements:
-
Wall mounted
-
Power supply connected
-
Panel Glass Break detection enabled
-
Armed “Away” or “Stay” depending
on programming
Detection Area
-
90° Line of sight
-
No obstacles
-
3ft Minimum from the panel up to 15ft max
Glass Requirements
-
Tempered Glass - 1/8” t0 1/4”
-
Plated Glass - 1/8” to 1’4”
-
Insulated Glass - 1/8” to 1/4”
-
Window must be framed
-
Minimum Dimensions 12” by 12”