Burglary Alarm Confirmation
When enabled, a confirmed alarm requires two sequential burglary alarms within the
Burglary Alarm Confirmation Timer window. NOTE: This setting is greyed out and unavailable unless EN
Grade 2 is enabled.
Burglary Alarm Confirmation Timer
Timer used for Burglary Alarm Confirmation. NOTE: This setting is greyed out and unavailable unless EN
Grade 2 is enabled.
Severe Weather Siren Warning
When enabled, siren will sound when the panel receives a severe weather alert. When
disabled, panel will use severe weather chime
Amount of time (in seconds) before panel will attempt call to central station after an alarm
event is triggered!
When SIA Limits enabled: :15 to :45 seconds!
When SIA Limits disabled: :0 to :254 seconds
Determine how long before siren stops sounding during an alarm event (4 minutes to 15
minutes). NOTE: For UL/cUL residential fire/burg applications the minimum bell timeout shall be set to 5 min. For
UL Commercial Burglary installations, minimum bell time out shall be set to 15 minutes.
Water/Freeze Siren/Temperature
When enabled, siren will sound when a water or freeze detector is triggered. When
disabled, the panel emits a āwaterā tone