505429-JTG-L-0512
Johnson Controls Unitary Products 3
Nomenclature
Product Category
Y = Split System, Condenser, AC, R-410A
Product Identifier
C = Standard Efficiency, 2-Pipe, R-410A
D = Standard Efficiency, 4-Pipe, R-410A
Nominal Cooling Capacity - MBH
J07 = 7.5 Ton
J10 = 10 Ton
J12 = 12.5 Ton
J15 = 15 Ton
J20 = 20 Ton
J25 = 25 Ton
C00 = Cooling Only
Product Options
Installation Options
A = None
2 = 208/230-3-60
4 = 460-3-60
5 = 575-3-60
Configured Split Condenser Model Number Nomenclature
A = Standard Motor
Airflow
Product Generation
1 = First Generation
2 = Second Generation
Voltage
Heat Type & Nominal Heat Capacity
J20
Y
C00 A
2
A
AA
2
A
Product Style
A = Style A
P = Split System, Condenser, HP, R-410A
2 = Non Pwr’d Conv Outlet
1 = Disconnect
T = Options 1 & 5
S = Options 5
D = Options 1 & 2
C = Option 2
B = Option 1
Options
5 = Pwr’d Conv Outlet
C
AA = None
AB = Phase Monitor
AC = Coil Guard
AE = Phase Monitor + Coil Guard
EA = ElectroFin Condenser Coil
EB = ElectroFin Condenser Coil + Phase Monitor
EC = ElectroFin Condenser Coil + Coil Guard
EE = ElectroFin Condenser Coil + Coil Guard
+ Phase Monitor
LA = Low Ambient
LB = Low Ambient + Phase Monitor
LC = Low Ambient + Coil Guard
LD = Low Ambient + Phase Monitor
+ Coil Guard
LE = Low Ambient + Technicoat Cond. Coil
LF = Low Ambient + Technicoat Cond. Coil
+ Phase Monitor
LG = Low Ambient + Technicoat Cond. Coil
+ Coil Guard
LH = Low Ambient + Technicoat Cond. Coil
+ Phase Monitor + Coil Guard
LJ = Low Ambient + ElectroFin Cond. Coil
LK = Low Ambient + ElectroFin Cond. Coil
+ Phase Monitor
LL = Low Ambient + ElectroFin Cond. Coil
+ Coil Guard
LM = Low Ambient + ElectroFin Cond. Coil
+ Phase Monitor + Coil Guard
TA = Technicoat Condenser Coil
TB = Technicoat Condenser Coil + Phase
Monitor
TC = Technicoat Condenser Coil + Coil Guard
TE = Technicoat Condenser Coil + Coil Guard
+ Phase Monitor
Product Category
N = Split System, Air Handler, AC & HP R-410A
Product Identifier
C = Standard Efficiency, 2-Pipe, R-410A
D = Standard Efficiency, 4-Pipe, R-410A
Nominal Cooling Capacity - MBH
J07 = 7.5 Ton
J10 = 10 Ton
J15 = 15 Ton
J20 = 20 Ton
J25 = 25 Ton
C00 = Cooling Only
Product Options
Installation Options
A = None
2 = 208/230-3-60
2
4 = 460-3-60
2
5 = 575-3-60
6 = 208/230/460-3-60
Configured Split Air Handler Model Number Nomenclature
B = 1.5 HP Motor
C = 2.0 HP Motor
D = 3 HP Motor
E = 5 HP Motor
F = 7.5 HP Motor
N = None (Motor Drive Kit Req)
1
Airflow
Product Generation
1 = First Generation
2 = Second Generation
Voltage
Heat Type & Nominal Heat Capacity
N
C
J20
C00 B
6
A
AA
2
A
Product Style
A = Style A
1. Motors are not shipped with
25 Ton Air Handler Units.
AA = No Options Installed
EJ = ElectroFin Evaporator Coil
TJ = Technicoat Evaporator Coil
2. J20NC/ND Airflow Option
“F” Only.