COOLING PERFORMANCE DATA
CONDENSING UNIT MODEL NO. RHP14J244S21
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM 600 800 1000
ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C. 21.7 23.6 23.5 25.2 26.6 23.4 24.1 24.3 26.0 27.2 25.1 24.6 25.1 26.9 27.8
S.C. 21.4 19.4 16.6 16.2 13.7 23.1 21.8 18.5 17.9 14.3 24.8 24.3 20.5 19.5 15.0
KW 1.20 1.22 1.22 1.23 1.21 1.28 1.29 1.31 1.29 1.28 1.36 1.35 1.39 1.35 1.35
75
T.C. 20.8 22.3 22.2 24.0 25.7 22.4 23.0 23.0 24.8 26.3 24.1 23.8 23.8 25.7 26.9
S.C. 20.5 18.8 16.0 15.7 13.1 22.1 21.1 18.0 17.5 13.9 23.8 23.5 19.9 19.2 14.6
KW 1.36 1.37 1.37 1.38 1.39 1.45 1.45 1.45 1.46 1.47 1.53 1.53 1.53 1.53 1.54
85
T.C. 19.8 20.9 20.9 22.9 24.8 21.4 21.9 21.6 23.7 25.5 23.1 22.9 22.4 24.5 26.1
S.C. 19.5 18.2 15.4 15.3 12.5 21.2 20.4 17.4 17.1 13.4 22.8 22.6 19.4 18.9 14.3
KW 1.52 1.53 1.53 1.54 1.57 1.61 1.61 1.59 1.62 1.65 1.70 1.70 1.66 1.71 1.73
95
T.C. 18.8 19.5 19.6 21.8 23.9 20.5 20.8 20.3 22.5 24.6 22.1 22.1 21.1 23.2 25.3
S.C. 18.6 17.5 14.8 14.8 11.9 20.2 19.7 16.8 16.7 12.9 21.8 21.8 18.8 18.7 14.0
KW 1.67 1.68 1.68 1.69 1.75 1.77 1.78 1.74 1.79 1.83 1.87 1.87 1.79 1.89 1.92
105
T.C. 17.7 18.0 18.0 20.2 22.4 19.2 19.3 18.7 20.9 23.1 20.7 20.7 19.4 21.6 23.7
S.C. 17.4 16.8 14.1 14.2 11.3 18.9 18.7 16.1 16.1 12.4 20.5 20.5 18.2 18.1 13.5
KW 1.86 1.87 1.87 1.90 1.96 1.97 1.97 1.94 2.00 2.04 2.07 2.07 2.02 2.09 2.12
115
T.C. 16.5 16.4 16.4 18.7 20.9 17.9 17.9 17.0 19.3 21.6 19.4 19.4 17.7 20.0 22.2
S.C. 16.3 16.1 13.4 13.5 10.8 17.7 17.6 15.4 15.5 11.9 19.2 19.2 17.5 17.5 13.0
KW 2.05 2.05 2.05 2.11 2.16 2.16 2.16 2.15 2.21 2.24 2.26 2.26 2.24 2.30 2.32
125
T.C. 15.3 14.8 14.8 17.1 19.4 16.7 16.4 15.4 17.7 20.0 18.1 18.1 16.1 18.3 20.6
S.C. 15.1 14.8 12.7 12.9 10.2 16.5 16.4 14.7 14.9 11.3 17.8 17.8 16.1 16.9 12.5
KW 2.25 2.24 2.24 2.33 2.37 2.35 2.35 2.35 2.42 2.45 2.46 2.46 2.46 2.51 2.52
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Air Handler Coil T.C. S.C. KW
– FC/MC/PC32 0.99 0.98 1.09
– FC/MC/PC35 0.99 0.98 1.09
– FC/MC/PC37 1.00 0.99 1.09
– FC/MC/PC43 1.00 0.99 1.09
RFCX24BE – 1.00 1.01 1.00
RFCX30BE – 1.00 1.01 1.00
RFCX24BP – 0.99 0.96 1.04
Furnace Coil T.C. S.C. KW
RGF19*AE10 FC/MC/PC32A 0.99 0.94 1.00
RGF19*AE10 FC/MC/PC37A 0.99 0.94 1.00
RGF19*BE12 FC/MC/PC35B 1.01 1.01 0.97
RGF19*BE12 FC/MC/PC43B 1.03 1.06 0.97
RGF19*CE16 FC/MC/PC35C 1.01 0.99 0.97
RGF19*CE16 FC/MC/PC43C 1.02 1.02 0.97
RGF19*CE20 FC/MC/PC35C 1.02 1.03 0.99
RGF19*CE20 FC/MC/PC43C 1.02 1.02 0.98