810754-UTG-C-0214
4 Johnson Controls Unitary Products
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
14.5 SEER HP WITH AIR HANDLERS
RHP14J184S21
RFCX24BE 17.5 585 18.0 13.3 14.50 12.00
RFCX30BE 17.5 660 18.0 13.1 15.00 12.50
RFCX24BP 17.5 675 18.0 13.1 13.00 11.00
RHP14J244S21
RFCX24BE 17.5 825 23.0 17.4 15.00 12.50
RFCX30BE 17.5 800 23.0 17.4 15.00 12.50
RFCX24BP 17.5 740 22.2 16.0 13.25 11.35
RHP14J304S21
RFCX36CE 21.0 1000 30.0 21.7 15.00 12.50
RFCX36BP 17.5 1060 28.8 22.0 13.25 11.35
RHP14J364S21
RFCX36CE 21.0 1275 36.0 27.4 14.50 12.00
RFCX42DE 24.5 1275 36.0 26.4 15.00 12.50
RFCX48DE 24.5 1195 35.8 26.6 14.50 12.00
RFCX36BP 17.5 1245 35.4 26.2 13.00 11.00
RFCX42CP 21.0 1230 35.6 26.4 13.35 11.45
RHP14J424S21
RFCX48DE 24.5 1125 39.5 27.0 15.00 12.50
RFCX60DE 24.5 1350 39.0 28.8 14.50 12.00
RFCX48DP 24.5 1320 39.5 28.4 13.25 11.35
RHP14J484S21
RFCX48DE 24.5 1295 45.5 30.8 14.00 12.00
RFCX60DE 24.5 1310 47.0 31.6 15.00 12.50
RFCX48DP 24.5 1320 44.5 30.2 13.25 11.35
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80 °F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95 °F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
STAGE
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
14.5 SEER HP WITH AIR HANDLERS
RHP14J604S21 RFCX60DE 24.5
1 1160 46.0 29.8
15.00 12.20
2 1835 57.0 41.0
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80 °F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95 °F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.