810754-UTG-C-0214
Johnson Controls Unitary Products 5
MA Modular Air Handlers use Coil Only Ratings.
Furnaces that are listed individually in the above table, such as the RGF1L*P, RGF19*P, and RGF1L*E use Coil Only Ratings.
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT MODEL
COIL
CFM RANGE
(Min.-max.)
STAGE
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER
1
EER
TOTAL SENS.
14.5 SEER HP COIL ONLY RATINGS
RHP14J184S21
FC/MC/PC32 14.5 450 - 750 600 18.0 12.6 13.25 11.35
FC/MC/PC35 17.5,21.0 450 - 750 600 18.0 12.6 13.20 11.35
FC/MC/PC37 14.5 450 - 750 600 18.0 13.2 13.25 11.35
FC/MC/PC43 17.5,21.0 450 - 750 600 18.0 13.2 13.25 11.35
RHP14J244S21
FC/MC/PC32 14.5 600 - 1000 800 22.2 16.3 13.25 11.35
FC/MC/PC35 17.5,21.0 600 - 1000 800 22.4 16.3 13.20 11.35
FC/MC/PC37 14.5 600 - 1000 800 22.4 16.6 13.25 11.35
FC/MC/PC43 17.5,21.0 600 - 1000 800 22.4 16.6 13.25 11.35
RHP14J304S21
FC/MC/PC37 14.5 800 - 1200 1000 28.6 21.6 13.25 11.35
FC/MC/PC43 17.5,21.0 800 - 1200 1000 28.4 21.6 13.50 11.35
RHP14J364S21
FC/MC/PC37 14.5 1000 - 1400 1200 35.0 25.6 13.00 11.00
FC/MC/PC43 17.5,21.0 1000 - 1400 1200 35.0 25.8 13.00 11.00
FC/MC/PC48 21.0,24.5 1000 - 1400 1200 35.2 25.8 13.35 11.45
FC/MC/PC60 21.0,24.5 1000 - 1400 1200 35.6 26.0 13.35 11.45
UC48 21.0,24.5 1000 - 1400 1200 35.0 26.0 13.25 11.35
UC60 21.0,24.5 1000 - 1400 1200 35.0 25.6 13.25 11.35
RHP14J424S21
FC/MC/PC60 21.0,24.5 1200 - 1600 1200 39.0 27.0 13.25 11.35
FC/MC62 24.5 1200 - 1600 1400 38.0 27.8 13.00 11.00
RHP14J484S21
FC/MC/PC60 21.0, 24.5 1400 - 1800 1400 45.5 31.6 13.25 11.35
FC/MC62 24.5 1400 - 1800 1600 48.0 34.2 14.00 12.00
FC64 24.5 1400 - 1800 1400 48.0 32.0 14.00 12.00
RHP14J604S21
FC/MC62 24.5 1150 - 1550 1 1350 48.0 31.8 13.30 11.35
FC/MC62 24.5 1600 - 2000 2 1800 56.5 39.5 13.30 11.35
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
COOLING CAPACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
FURNACE
COIL
1
MODEL
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
14.5 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
2
RHP14J184S21
RGF19*AE10 14.5 FC/MC/PC32A 600 18.0 13.5 14.50 12.50
RGF19*AE10 14.5 FC/MC/PC37A 600 18.0 13.4 13.50 11.35
RHP14J244S21
RGF19*AE10 14.5 FC/MC/PC32A 775 22.2 16.5 13.25 11.35
RGF19*AE10 14.5 FC/MC/PC37A 800 22.4 16.8 13.50 11.35
RGF19*BE12 17.5 FC/MC/PC35B 800 22.4 16.7 13.70 11.35
RGF19*BE12 17.5 FC/MC/PC43B 800 22.6 16.9 14.00 12.00
RGF19*CE16 21.0 FC/MC/PC35C 800 22.4 16.6 13.50 11.35
RGF19*CE16 21.0 FC/MC/PC43C 800 22.6 16.8 13.50 11.35
RGF19*CE20 21.0 FC/MC/PC35C 800 22.6 16.7 14.20 12.00
RGF19*CE20 21.0 FC/MC/PC43C 800 22.8 17.0 14.20 12.00
RHP14J304S21
RGF19*BE12 17.5 FC/MC/PC43B 975 29.0 21.6 15.10 12.50
RGF19*CE16 21.0 FC/MC/PC43C 1000 29.0 21.6 15.10 12.50