COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
— = Not Applicable.
MA Modular Air Handlers use Coil Only Ratings.
* Notates “Hot Heat Pump” performance. These ratings are not AHRI Listed.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
— = Not Applicable.
MA Modular Air Handlers use Coil Only Ratings.
HEATING CAPACITY - With Air Handler Coils
UNIT
MODEL*
AIR
HANDLER
COIL
1
MODEL
1. Rated CFM same as for cooling.
HEATING
2
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.
47F17F HSPF
MBH COP KW MBH COP KW STD
14.5 SEER HP WITH AIR HANDLERS
RHP14J184S21
RFCX24BE – 18.0 3.82 1.38 11.0 2.50 1.29 8.20
RFCX30BE – 18.03.881.3610.92.541.268.50
RFCX24BP – 18.0 3.56 1.52 11.4 2.34 1.43 7.75
RHP14J244S21
RFCX24BE – 22.23.681.7713.72.441.658.50
RFCX30BE – 22.23.681.7713.72.441.658.50
RFCX24BP – 22.43.421.9213.92.301.777.75
RHP14J304S21
RFCX36CE – 30.04.082.1520.42.622.289.00
RFCX36BP – 30.03.762.4219.42.502.277.75
RHP14J364S21
RFCX36CE – 34.6 3.80 2.67 20.2 2.80 2.11 8.50
RFCX42DE – 34.6 3.80 2.67 20.2 2.80 2.11 9.00
RFCX48DE – 33.83.742.6519.82.782.098.50
RFCX36BP – 35.03.522.9120.82.582.368.20
RFCX42CP – 34.83.562.8620.82.622.338.20
RHP14J424S21
RFCX48DE – 39.53.703.1325.42.662.809.00
RFCX60DE – 39.03.783.0225.42.682.788.50
RFCX48DP – 40.53.523.3726.42.503.098.50
RHP14J484S21
RFCX48DE – 47.03.444.0028.82.443.468.20
RFCX60DE – 47.03.723.7030.42.623.409.00
RFCX48DP – 48.03.224.3729.62.263.847.80
HEATING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR
HANDLER
COIL
1
MODEL
HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF COP @ 47
47 OD 17 OD
14.5 SEER HP WITH AIR HANDLERS
RHP14J604S21 RFCX60DE –
1116043.0– –3.36
2 1835 58.0 40.0 9.00 3.70
2* 1160 55.0 39.5 8.85 3.00
1. Rated CFM same as for cooling.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.