810754-UTG-C-0214
8 Johnson Controls Unitary Products
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
MA Modular Air Handlers use Coil Only Ratings.
Furnaces that are listed individually in the above table, such as the RGF1L*P, RGF19*P, and RGF1L*E use Coil Only Ratings.
— = Not Applicable.
* Notates “Hot Heat Pump” performance. These ratings are not AHRI Listed.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
MA Modular Air Handlers use Coil Only Ratings.
Furnaces that are listed individually in the above table, such as the RGF1L*P, RGF19*P, and RGF1L*E use Coil Only Ratings.
— = Not Applicable.
HEATING CAPACITY - Upflow, Downflow, and Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT
MODEL*
COIL
1
MODEL
HEATING
2
47 F 17 FHSPF
MBH COP KW MBH COP KW STD
14.5 SEER HP COIL ONLY RATINGS
RHP14J184S21
FC/MC/PC32 18.0 3.56 1.52 11.4 2.34 1.43 7.75
FC/MC/PC35 18.0 3.52 1.56 11.3 2.34 1.45 7.70
FC/MC/PC37 18.0 3.62 1.50 11.3 2.40 1.38 7.75
FC/MC/PC43 18.0 3.62 1.50 11.3 2.40 1.38 7.75
RHP14J244S21
FC/MC/PC32 22.83.401.9614.22.261.847.75
FC/MC/PC35 22.63.381.9915.42.261.867.70
FC/MC/PC37 22.83.401.9614.22.261.847.75
FC/MC/PC43 22.83.401.9614.22.261.847.75
RHP14J304S21
FC/MC/PC37 30.03.722.4319.32.482.288.00
FC/MC/PC43 30.03.702.4319.42.582.228.00
RHP14J364S21
FC/MC/PC37 35.03.522.9120.82.582.368.20
FC/MC/PC43 35.03.522.9120.82.582.368.20
FC/MC/PC48 34.83.522.9020.82.602.348.20
FC/MC/PC60 35.43.642.8521.22.662.348.20
UC48 36.03.702.8521.42.662.367.80
UC60 36.03.682.8720.82.602.347.80
RHP14J424S21
FC/MC/PC60 40.53.523.3726.02.523.028.50
FC/MC62 40.03.543.3126.22.523.058.50
RHP14J484S21
FC/MC/PC60 48.03.444.0929.62.383.647.80
FC/MC62 48.03.763.7431.42.583.578.20
FC64 48.03.763.7431.62.603.568.20
1. Rated CFM same as for cooling.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.
HEATING CAPACITY - With Upflow, Downflow, & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT
MODEL*
COIL
1
MODEL
1. Rated CFM same as for cooling.
HEATING
2
2. Heating MBH based on AHRI standards of 70° DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.
STAGE
RATED
CFM
NET MBH
HSPF COP @ 47
47 OD 17 OD
14.5 SEER HP COIL ONLY RATINGS
RHP14J604S21 FC/MC62
1 1350 43.5 – – 3.42
2 1800 60 40.5 8.4 3.58
2* 1350 57 40.0 8.6 3.36