56/69
Document 10000028013-DOC-000-00-EN
we know what‘s cooking
With the AutoTemp 16 control, the current menu item and the associated value are shown alternately in
the temperature display. The value is set using the arrow keys and saved by pressing heating- .
When a value has been saved, the next menu item will appear.The user menu is exited when the last
parameter has been saved and the display shows ‘---’.The user menu will be cancelled if the user press-
es or if no key is pressed for two minutes.
Item Description Selection
00.0 Shows software
00.1 Shows software version
1.0 Should the access code function be active? 0 = Inactive
1 = Active
1.1 Select access code 0000-9999
This item is only shown if 1.0 = 1
2.1 Select return tilt time 0.0 - 3.0 seconds. 0.0 = Off
2.2 Select the delay before return tilt is activated 0.0 - 3.0 seconds
This item is only shown if 2.1 is set to
be greater than 0.0
3.1 Is water filling permitted with the kettle tilted? 0 = No
1 = Yes
3.2 Is water filling permitted with a closed lid? 0 = No
1 = Yes
4.0 Specify method used to control water quantity.
Only relevant when factory settings menu item
60.2 = 0
1 = Estimated water quantity
2 = Time
4.1 Specify the conversion factor from quantity of
water to minutes.
Only relevant when user menu item 4.0 = 1.
1.0 – 999.9 units, e.g. litre/minute.
Adjust until the water quantity is ap-
propriate.
4.2 Select the number of impulses from the water
flow meter per litre.
Only relevant when factory settings menu item
60.2 = 1.
0.1 - 999.9
Adjust until the quantity is appropri-
ate.
See the formula for calculating a new
constant in the service instructions.
4.3 Specify the factor for the number of impulses
from the water flow meter selected in the user
menu, item 4.2
1.0 - 100.0
5.1 Select the chilling power for water-saving chilling 1-9
When this value is set to 9, the water
quantity will not be reduced.
6.1 Select the RPM for PowerMixing 5 - 80 RPM
6.2 Select the RPM for SlowMix
Only relevant if factory settings menu item 91.0
= 1.
5 - 30 RPM
7.0 Select the type of acoustic signal 0 = No signal
1 = Beeper sounds periodically