we know what‘s cooking
69/69
Document 10000028013-DOC-000-00-EN
CAUTION!
If the kettle is switched off before the safety pressure control is engaged error E99 will occur. The
procedure is then to switch of the supply to the kettle and wait until the pressure has dropped to
below 0.8 bar.
Testing steam-heated kettles
On steam-heated kettles, a check must be performed to ensure that the safety valve and reduction valve
on the fixed installation upstream of the kettle is working correctly. The procedure for this test depends
on the fixed installation.A check must also be made to ensure that the safety pressure switch on the ket-
tle is operating correctly. This can only be done by increasing the pressure in the kettle.Refer also to the
regulations for the fixed installation.
NOTICE!
The valve on the kettle is an over-pressure valve and must not be considered as a safety valve
which must be placed in the fixed installation.