EasyManuals Logo

Jøtul F 305 User Manual

Jøtul F 305
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
4
ENGLISH
3.0 Safety
NB! To guarantee optimal performance and safety, Jøtul
recommends that its stoves are tted by a quali ed
installer (see www.jotul.com for a complete list of dealers).
Any modi cations to the product by the distributor, installer or
consumer may result in the product and safety features not
functioning as intended. The same applies to the installation of
accessories or optional extras not supplied by Jøtul. This may
also be the case if parts that are essential to the functioning and
safety of the replace have been disassembled or removed.
In all these cases, the manufacturer is not responsible or liable
for the product and the right to make a complaint becomes null
and void.
3.1 Fire Prevention Measures
There is a certain element of danger every time you use
your replace. The following instructions must therefore be
followed:
The minimum safety distances when installing and using
the replace are given in g. 1.
Ensure that furniture and other ammable materials are
not too close to the replace. Flammable materials should
not be placed within 1100 mm of the replace.
• Allow the re to burn out. Never extinguish the ames with
water.
• The replace becomes hot when lit and may cause burns
if touched.
Only remove ash when the replace is cold. Ash can
contain hot embers and should therefore be placed in a
non- ammable container.
Ash should be placed outdoors or be emptied in a place
where it will not present a potential re hazard.
In case of chimney re:
Close all hatches and vents.
• Keep the rebox door closed.
Check the loft and cellar for smoke.
• Call the re service.
Before use after a re an expert must check the replace
and the chimney in order to ensure that it is fully functional.
3.2 Floor
Foundation
You need to make sure the foundation is suitable for a replace.
See “2.0 Technical Data” for speci ed weight.
We recommend the removal of any ooring that is not attached
to the foundation (“ oating oors”) beneath the installation.
Requirements for protection of wooden
ooring beneath the replace
The product with base has integrated oor protection and
may therefore be placed directly on a wooden oor.
Jøtul F 305 with legs must have a oorplate below and in
front according to national laws and regulations.
Important! The space under the burnchamber of Jøtul F 305
with legs cannot be used for storage.
Any in ammable oor coverings, such as linoleum, carpets,
etc. must be removed from under the product.
Requirements for protection of
in ammable oors in front of the
replace
The front plate must comply with national laws and regulations.
Contact your local building authorities regarding restrictions
and installation requirements.
3.3 Walls
Distance to walls made of combustible material - see g. b
Distance to combustible wall protected by firewall: See g. 1c.
The replace may be used with an uninsulated ue pipe
provided the distances between the replace and walls made
of combustible materials are as shown in g. 1b. Alternative
distances with shielded or insulated ue pipe are also
displayed in g. 1b.
Note! Ensure that furniture and other ammable materials
are not too close to the replace. Flammable materials
should not be placed within 1100 mm of the replace.

Other manuals for Jøtul F 305

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jøtul F 305 and is the answer not in the manual?

Jøtul F 305 Specifications

General IconGeneral
TypeWood Stove
MaterialCast Iron
Flue OutletTop or Rear
Flue Size6 inches
EPA CertifiedYes
Emissions2.5 g/h
Heating Capacityup to 1, 200 sq. ft.