Selectable analog bandwidth limit,
typical
Typical 20 MHz (reduced to 6 MHz when
using a 1x probe)
Low frequency response (-3db)
≤ 10 Hz
DC gain accuracy 10V/div - 10mV/div ±3% for normal or
Trigger
Type Edge
Mode Auto, Normal, Single
Level ± 4 divisions from centre of screen
Trigger level accuracy 0,2 div*volts/div within 4 div.
Slope Rising, falling, rising & falling
Source CH1, CH2
Input
Coupling DC, AC or GND
Input impedance (DC coupled)
25pF ±3pF, 1MΩ ±2%
Probe attenuation 1X, 10X
Supported probe attenuation factors 1X, 10X, 100X, 1000X
Input protection voltage 150 V
RMS
Measurement
Values between cursors Voltage Dierence: △V
Time Dierence: △T
Automatic measurement Frequency, Amplitude
General specifications
Display type 2.6 inch 64K color TFT-LCD
Display resolution 320 horizontal x 240 vertical pixel
Display contrast Adjustable
Power supply voltage 100-240V AC, 50-60Hz OR 5V DC, 2A
Power consumption < 2.5 W
Fuse T, 3 A
Battery 2 x 2600 mAh
Operating temperature 0– 50°C
Storage temperature -20-60°C