- 9 -
8 ATEX CAUTIONS
8.1 Special conditions for safe use
The equipment is an intrinsically safe equipment. It can be used in a potentially explosive
atmosphere.
The equipment must be powered only by the battery JRC type BP-227AXD.
When the transceiver is used in a hazardous areas, either the jack cover or HM-138 must be
attached to the connector. Failure to do this will make the radio ATEX non-compliant and may
result in an accident during use in hazardous areas.
The battery shall be charged only in non hazardous areas.
Ambient operating temperature: –20
°C to +55°C
8.2 Meaning of ATEX marking codes
Ambient tem
erature
CE conformity
marking
Identification number of notified
body (where appropriate)
(LCIE: 0081)
Equipment category:
1 (for Zone 0 or 20), 2 (for Zone 1 or 21),
3 (for Zone 2 or 22)
Type of Explosive atmosphere:
G (for gas, vapors and mist), D (for dusts)
Equipment group: I(for mines), II(for other than mines)
Intrinsic safety
according EN60079-0
Gas Group (see Fig. 1)
Gas/Equipment
Protection Level (EPL)
Explosion
protection marking
Equipment conforms to types of
protection standardized by CENELEC
(European standards)
Marking temperatures (see Fig. 1)
Dust Group
Dust/Equipment
Protection Level (EPL)
Intrinsic safety
according
EN60079-0
EN60079-31
Protection
by enclosures
Max surface
temperature
IP Code