3-2
Table 3-1 The status of MES which LED lamps indicated
(An opening number of the button name corresponds to Figure 2-2-2a.)
NAME ON OFF
(2) POWER lamp MES power on MES power off
(3) SYNC lamp Bulletin Board OK
When the MES is returned the NCS channel
to the TDM channel or the TDM channel to
the NCS channel, this LED blinks.
Bulletin Board NG
(4) LOG-IN lamp Logged in Logged out
(5) TRANSMIT lamp MES carrier on MES carrier off
(6) RECEIVE lamp Message receiving No message/ or outputting
received message to DTE or
printer
(7) ALARM lamp
・When TX Alarm *
1
is generated, it blinks at
intervals of 0.5 seconds.
・When Battery Alarm*
2
is generated, it blinks
with 1 second interval.
・When both of TX and Battery Alarms are
generated, it lights without blink.
Normal condition
(To extinction the lamp, turn on
and off the power switch.)
*1) TX Alarm informs some sort of malfunction is occurred on communication devices.
*2) Battery Alarm informs the battery is decreased to under the specified level.
The position data reporting might not be able to be transmitted normally when the battery alarm has been
generated, then contact JRC.
Table 3-2 Function of switch and buttons
Name Function Remarks
(1) POWER switch Power ON/OFF the MES.
(8) RESET button To reset the status of JUE-95LT when it
operates abnormally.
Refer to chapter 4-6 of this manual and
be careful to handle this button.
(It seems to a very little hole.
Press the switch existed in the hole with
narrow object like a wire.)
(9) DIMMER button To adjust the brightness of lamps to four
stages.
(Circulates between
Off-Low-Middle-High)
Table 3-3 Connectors and the Cable
Name Connected from/to
EME connector
IME⇒EME
Power Supply connector
IME⇒AC adapter of EXT PSU (24V)
DTE connector
IME⇒DTE and DS/DTE
Option Connector
IME⇒JB1 and JB2