– 87 –
(2) Releasing procedure of the warning
When the designated inspection time is reached, the warning
screen is displayed.
In case of clearing the inspection time, press CLEAR button
. The inspection time is cleared and the pop-up is closed. In case
of not clearing the inspection time, press CANCEL button
and close the pop-up. Every time one sewing is completed, the
warning screen is displayed until the inspection time is cleared.
Warning Nos. of the respective items are as follows.
• Needle replacement : A201
• Cleaning time : A202
• Oil replacement time : A203
For the grease-up portion, refer to the item of
"III-1-7. Replenishing the designated places with
grease" p.120
Perform clearing remaining time up to the replacement.
When button
of the item you desire to clear is pressed, the
time of replacement clear screen is displayed. When CLEAR
button
is pressed, the remaining time up to the re-
placement is cleared.
Display the threading diagram.
When threading button
displayed in the maintenance
and inspection screen is pressed, the needle thread threading
diagram is displayed.
Observe it when performing threading.