Behaviour after a mains voltage failure
All settings and time programs are retained. Any missed switching times are not ap-
plied later. The load output or the system insert outputs are switched off, provided the
parameter "Switching status after mains voltage returns" is set to its default setting.
If the device was not previously added to a Bluetooth Mesh network (project) by
means of the JUNG HOME app, it will switch to pairing mode for two minutes after
the mains voltage returns and the status LED will flash slowly at a regular interval in
blue.
Power failure shorter than power reserve (min. 4 hours)
Time and date are up to date
The following time programs are performed normally again
Power failure longer than power reserve (min. 4 hours)
The LEDs flash in blue three times repeatedly until the time is automatically
updated when connecting with the app
The time programs are not executed as long as the time is not up to date
JUNG HOME push-button 1-gang, JUNG HOME push-button 2-gang
6 / 26
32405203 24.02.2023
J0082405203

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jung Home and is the answer not in the manual?

Jung Home Specifications

General IconGeneral
TypeSwitch
Current Rating10 A
Frequency50 Hz
Protection ClassIP20
MaterialPlastic
ColorWhite
Voltage230V