LC300 LC420
Air flow under free air condition
l/min
m
3
/h
8500
510
12000
720
Air flow 60% vacuum rate
l/min
m
3
/h
6415
385
9000
540
Air flow 80% vacuum rate
l/min
m
3
/h
3450
207
4833
290
Max. vacuum at continuous duty (*) % 80
Max. vacuum % 92
Power required at max. vacuum kW 14 18
Power required at 0.5 relative bar (1.5 abs.) kW 12 16
Power required at 1.0 relative bar (2.0 abs.) kW 17 24
Max. relative pressure (abs.) bar 1 (2,0)
Air flow at 0.5 relative bar (1.5 abs.)
l/min
m
3
/h
7500
454
10830
650
Air flow at 1.0 relative bar (2,0 abs.)
l/min
m
3
/h
7000
420
9830
590
Oil consumption g/h 200 220
Oil tank capacity litres 4
Circulating pump speed rpm 2700
Circulating flow rate l/min 55
Heat exchange rate Kcal/h 6000 8000
Mass moment of inertia Kgm2 0.15 0.21
(*): at nominal speed and room temperature of 20° C.
Pressure operation: free inlet
Vacuum operation: free outlet
Free
port
Vacuum Pressure
0% 20% 40% 60% 70% 80% 90% 1.4 bar 1.8 bar 2.0 bar
LC 420
m
3
/h
l/min
kW
720
12000
11
670
11170
12
620
10330
14
540
9000
15
400
6670
16
290
4833
16,5
16
270
17
650
10830
16
610
10170
21
590
9830
24
LC 300
m
3
/h
l/min
kW
510
8500
8
480
8000
9
444
7400
10
385
6420
11
285
4760
12
207
3450
13
10
190
14
460
7660
11
435
7250
15
420
7000
17
Room condition: P = 1013 mbar, T = 20° C Vacuum pump at max. speed.
Conveyed fluid: air density 1.2 kg/m
3.
PERFORMANCES
FLOW - POWER

Other manuals for jurop LC 420

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jurop LC 420 and is the answer not in the manual?

jurop LC 420 Specifications

General IconGeneral
Brandjurop
ModelLC 420
CategoryWater Pump
LanguageEnglish

Related product manuals