(No.PA062<Rev.001>) 7
1.6.3 HANDLING CAUTIONS
Use a cross-head screwdriver to take out and reinstall the lamp
unit. Refer to the INSTRUCTIONS.
Observe the following cautions.
- Be sure to disconnect the power cord from the AC power
source.
- The lamp remains quite hot after power off. Be sure to allow
plenty of time (30 minutes to 1 hour) to cool before proceed-
ing.
- The lamp can break if dropped or subjected to physical
shock.
- Use care not to directly touch or soil the lamp projecting
(glass) face.
When installing the lamp unit, ensure (or make sure) the inte-
rior projections of the lamp cover are securely inserted into the
holes of the projector. Since the lamp cover projections en-
gage the interlock switch part of the protector circuit (normal
operating state), be sure the cover is properly positioned and
secure with screws.
Do not place the removed lamp unit at locations that is reach-
able by children or near combustible items.
Dispose used lamp units in the same way as fluorescent
lamps. Follow your local community rules for disposal.
1.6.4 LAMP USE TIME RESET
Be sure to reset the Lamp use time after replacing the lamp
unit. Unless reset, the projector will cease operation (lamp will
not light).
* Conversely, reset the use time only after replacing the lamp.
RESET THE LAMP TIME FROM THE MENU SCREEN
(1) Display the setting menu.
(2) Select "Function" "Lamp Reset"
(3) Select "Yes" and the lamp time is set to zero.
RESET THE LAMP TIME BY REMOTE CONTROL
(1) Set for stand-by mode.
(2) In sequence, press the [BACK], [OK] and [HIDE] buttons
of the remote control unit.
(3) Press the [] button for more than 2 seconds.
(4) The STAND-BY and LIGHT LEDs alternately flash for
about 3 seconds, then only the STAND-BY LED lights
steadily.