ComboGard Pro locks can either be configured using the ComboGard Pro Setup software or through
a series of keypad commands. This document will cover configuring the lock using the keypad
commands ONLY.
The ComboGard Pro Lock has three states of operation: Factory Default, Manual Setup, and
Active. ComboGard Pro locks are shipped from LA GARD in Factory Default state without Users or
features enabled.
Factory Default: The Lock must be in the Factory Default state to be programmed by the PC
software.
Factory mode functions as follows:
1 key – When pressed, will open the Lock.
0 key – When pressed, prompts the ComboGard Pro Setup software to send the configuration
settings to the Lock.
OR if pressed and held, places the Lock into Manual Setup.
All other keys perform no function.
Manual Setup: The Lock can be configured using the keypad only.
Active: To activate the Lock and freeze the configuration, the Manager combination MUST
be changed.
WARNING: Add all required Users and complete Setup Configuration before changing the Manager’s
default combination from 5-5-5-5-5-5. Once the combination is changed, NO ADDITIONAL USERS
can be added.
PROGRAMMABLE LOCK FEATURES
MODES (Multiple Modes may be selected.)
Silent Alarm (Alarm Box Required)
If enabled, this option will send a signal to an outside alarm system through the LA GARD
Alarm Box.
Dual Mode
If enabled, two combinations will be required to operate the Lock.
The Manager and one additional User must be active.
Time Delay Override
If enabled, User 9 can override delay period.
User 9 must be active.
EXTERNAL SIGNALS (Alarm Box Required - P/N 2789NC. Only one External Signal type may
be selected.)
An external input signal to the Alarm Box will either disable the Lock from opening, override the time
delay, or enable the remote override depending on the selection programmed for External Signals.
External Signal disables Lock opening with valid combination.
NOTE: When configuring the ComboGard Pro Lock using the keypad only, the Disable Opening
option is enabled by default and cannot be changed.
OR External Signal overrides Time Delay. (This option is ONLY available if enabled using Setup
software.)
OR External Signal enables the Remote Override. (This option is ONLY available if enabled using
Setup software, and with Lock code level 39E v1.09 or higher.)
KEYPAD ONLY SETUP INSTRUCTIONS
COMBOGARDPRO
39E Electronic Combination Lock
Question and Answer IconNeed help?

Do you have a question about the Kaba Mas LA GARD COMBOGARDPRO 39E and is the answer not in the manual?

Kaba Mas LA GARD COMBOGARDPRO 39E Specifications

General IconGeneral
BrandKaba Mas
ModelLA GARD COMBOGARDPRO 39E
CategoryLocks
LanguageEnglish

Summary

Keypad Only Setup Instructions

Factory Default State

Lock must be in Factory Default state for PC programming. Key functions are described.

Manual Setup

Lock configuration can be performed using the keypad only.

Active State

Lock is activated and configuration frozen by changing the Manager combination.

Programmable Lock Features

Lock Modes

Options include Silent Alarm, Dual Mode, and Time Delay Override.

External Signals

External input signals can disable opening or override time delay.

Time Delay and Combination Length

Time Delay Settings

Configurable Delay Period (1-99 min) and Open Period (1-19 min).

Combination Length

Combination length can be set from six (6) to nine (9) digits.

Lock Users and Management

Manager Capabilities

Manager can open, change combo, manage users, set delays, and audit.

User Capabilities

Up to 9 users can open the lock and change their combinations.

Standard Lock Features

Wrong Try Penalty

Four consecutive invalid entries trigger a five-minute delay penalty.

Low Battery Warning

Signals indicate low battery; operation stops when critically low.

Audit Records

Records last 63 events; accessible by Manager with software.

Lock Responses

Standard Operation Signals

LED flashes and beeps indicate operation status: single, double, or triple signals.

Additional Operation Signals

Signals for delay, penalty, and low battery warnings are described.

Super Master Reset (SMR)

SMR Process

Steps to reset the lock to factory state, preserving the SM code.

SMR Command Options

Options include changing the Super Master code or resetting the lock.

Program the Lock

Exit Factory State

Procedure to move the lock from Factory Default to Manual Setup.

Set Combination Length

Instructions for setting the desired combination length.

Configure Lock Modes

Lock Mode Selection

Table details configurations for Time Delay Override, Dual Mode, and Duress Alarm.

Activate Users

User Enrollment

Steps to enroll new users, including combination entry and confirmation.

Set Time Delay Values

Time Delay Period Settings

How to set Delay and Open Periods via keypad commands.

Activate the Lock

Manager Combination Change

Change the Manager combination to activate the lock and freeze settings.

Reset the Lock

Lock Reset Procedure

Steps to reset the lock to Factory mode using a reset box.