Powador 2500xi
3600xi | 4000xi
4500xi | 5000xi
The next generation of transformerless inverters with
an integrated DC disconnector.
Operating instructions
Operator
Skilled and authorised electrician

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Kaco Powador 4500xi and is the answer not in the manual?

Kaco Powador 4500xi Specifications

General IconGeneral
ModelPowador 4500xi
Rated Output Power4500 W
Maximum AC Power4500 W
Maximum DC Voltage600 V
Nominal AC Voltage230 V
Number of MPP Trackers1
CoolingNatural Convection
Protection DegreeIP54
TypeGrid-tie Inverter
Frequency Range50 Hz / 60 Hz
Operating Temperature Range-25°C to +60°C
Weight16.5 kg

Summary

Safety Instructions and Regulations

Danger due to lethal voltages.

Lethal voltages are present within the unit and on the power supply lines.

Accident prevention regulations

The inverter must be installed by an authorised electrician.

Notes on Installation and Operation

Operation

Overview of controls and displays

Explains the function of the display, LEDs, and control keys.

Troubleshooting

Impossible daily peak value displayed

Inverter continues to operate normally without losses to the yield.

Line fuse trips

Fuse capacity too low or damage to inverter hardware.

Display is blank

Unit in night shutdown mode or display module faulty.

Inverter does not start up, LED (1) off

Unit in night shutdown mode or no line voltage/generator voltage.