4.8 Safety devices
The following safety devices are provided and may not be modified in any way.
EMERGENCY STOP control device:
The EMERGENCY STOP button shuts down the compressor immediately. The motor remains
stopped. The pressure system is vented.
Pressure relief valve:
The pressure relief valve protects the system against excessive pressure. It is factory set.
Safety pressure switch (machine with refrigeration dryer):
The safety pressure switch protects the refrigerant circuit against excessive pressure. It cannot
be set.
Door interlock switches:
The machine will stop automatically if a safety interlocked door or panel is opened or removed.
Enclosures and guards for moving parts and electrical connections
Protect against accidental contact.
4.9 Keys and LEDs – SIGMA CONTROL BASIC
Fig. 7 Keys – overview
Item Name Function
1 «ON» Switch on the machine.
2 «OFF» Switch off the machine.
Resets alarms (acknowledge).
Resets the maintenance interval counter.
6 «DOWN» Scrolls down the parameter list.
Reduces a parameter value.
7 «UP» Scrolls up the parameter list.
Increases a parameter value.
8 «Escape» Exits the edit mode without saving.
4 Design and Function
4.8 Safety devices
9_5717 20 E
Service Manual Screw Compressor
ASK T SIGMA CONTROL BASIC
33