EasyManua.ls Logo

KAPSCH T600 User Manual

Default Icon
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
© Kapsch TrafficCom Canada Inc. 2022
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence
and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for
manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360420-835 REV F, T600 OPERATOR AND MAINTENANCE MANUAL.DOCX
Kapsch TrafficCom
T600 Tag Tester
Operator and Maintenance Manual
DOCUMENT: UM 360420-835
REVISION: F
DATE: 28 Mar 2022
Editor: Scott Garlick
REVIEWERS:
Ed Rolo Director of Programs
Dan Terrier Manager, Software Design
Japjeev Kohli Director, Engineering
Joe Bianchini Vice President, Operations
Rick Gegenheimer Vice President, Operations USA
Paul Manuel Vice President, Sales and Marketing
APPROVAL:
Richard Turnock VP Engineering& CTO

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the KAPSCH T600 and is the answer not in the manual?

KAPSCH T600 Specifications

General IconGeneral
Frequency Range9 kHz to 6 GHz
Input Impedance50 Ω
Input VSWR< 1.5:1
Maximum Input Level+30 dBm
Resolution Bandwidth1 Hz to 3 MHz
InterfaceUSB, GPIB
Power Supply100-240 VAC, 50/60 Hz

Summary

About This Manual

Warnings and Cautions

Provides essential safety information regarding potential risks and precautions for operating the T600 Tag Tester.

Overview

Introduction

Introduces the T600 Tag Tester, its purpose, and how it ensures OBU functionality through RF signal testing.

T600 System Components

Lists the hardware and software components required for the T600 Tag Tester system setup.

Operating Procedures

Starting Up the T600 Tag Tester

Details the step-by-step procedure for powering on the TTU and launching the T600 software.

Testing a Tag

Explains how to correctly orient an OBU and initiate testing using the T600 Tag Tester.

Entering the OBU Bar Code Number

Describes the process for manually entering OBU bar code information if the scanner fails.

Configuring Log Files

Guides users on how to configure the T600 to record OBU test results into specified log files.

Command and Controls

Details available commands, their execution methods, purpose, and who can execute them.

Theory of Operations

Calibration

Explains the calibration process performed by Kapsch service personnel to set test criteria for OBUs.

The Write Tests

Describes how write tests function, including data writing and setting a reserved memory bit.

The Burst Tests

Details the burst tests that ensure consistent OBU reading and writing, specifying success rate requirements.

Installation

System Requirements for Customer-Supplied Computer

Outlines the necessary hardware and software specifications for the computer used with the T600 Tag Tester.

Installing the T600 Software

Guides users through the step-by-step installation process of the T600 software on a customer-supplied computer.

Installing the T600 Hardware

Provides instructions for connecting the T600 Tag Tester hardware components and optional accessories.

T600 Connections

Details the specific cable connections required for the TTU, computer, and optional scanner.

Installing/Upgrading the Agency Mapping File

Explains how to install or update the agency mapping file for the T600 Tag Tester.

Configuring T600 Tag Tester Communication Settings

Guides the configuration of communication settings between the computer, TTU, and internal scanner.

Installing the Calibration Files

Details the process of installing optional calibration files unique to each tag tester for initial calibration.

Agency Mapping File Configuration for Tag Types

How to Identify Interior OBU (G4E) from the Older Model FPT (G3B)

Provides instructions on differentiating Interior OBU (G4E) from older FPT (G3B) using tag serial numbers.

How to Identify Exterior OBU (FME) from the Older Model LPT

Details how to distinguish Exterior OBU (FME) from the older LPT model using tag serial numbers.

Troubleshooting and Testing

Error Messages Indicating a Tag Failure

Lists common error messages related to OBU failures, with descriptions of their causes.

Troubleshooting Tree: Communications Error - Check Serial Connection

Provides a flowchart to diagnose and resolve serial connection errors between the PC and the T600.

Troubleshooting Tree: Test Fail - Tag Position Failure (IR Beam)

Offers a troubleshooting guide for errors related to the IR sensor detecting OBU position in the cradle.

Troubleshooting Tree: Tag Fail - Bar Code Mismatch with Tag Contents

Outlines steps to resolve errors where OBU bar code data does not match stored information.

Resolving a Missing Calibration File Error

Explains how to identify and resolve issues caused by missing calibration files for specific OBU types.

TTU Functional Check

Describes a procedure to check the TTU's functionality when consistent 'No response from tag' errors occur.

Maintenance Procedures

Preventive Maintenance Procedures and Scheduling

Outlines the recommended schedule and tasks for preventive maintenance of the T600 Tag Tester.

Appendix

G4 OBU

Illustrates the correct orientation of the G4 OBU within the TTU cradle.

Flat Pack Transponder (FPT)

Provides an illustration showing the correct placement of the Flat Pack Transponder (FPT) in the TTU cradle.

Front Mount Exterior (FME) OBU

Shows the correct orientation for the Front Mount Exterior (FME) OBU in the TTU cradle.

Roof Mount FTP

Illustrates the correct positioning of the Roof Mount FTP within the TTU cradle.

Front Mount OBU - Motorcycle

Depicts the correct orientation for the Front Mount OBU (Motorcycle) in the TTU cradle.

High Occupancy Toll (HOT) OBU

Illustrates the correct orientation for the High Occupancy Toll (HOT) OBU in the TTU cradle.