Do you have a question about the KAPSCH T600 and is the answer not in the manual?
Frequency Range | 9 kHz to 6 GHz |
---|---|
Input Impedance | 50 Ω |
Input VSWR | < 1.5:1 |
Maximum Input Level | +30 dBm |
Resolution Bandwidth | 1 Hz to 3 MHz |
Interface | USB, GPIB |
Power Supply | 100-240 VAC, 50/60 Hz |
Provides essential safety information regarding potential risks and precautions for operating the T600 Tag Tester.
Introduces the T600 Tag Tester, its purpose, and how it ensures OBU functionality through RF signal testing.
Lists the hardware and software components required for the T600 Tag Tester system setup.
Details the step-by-step procedure for powering on the TTU and launching the T600 software.
Explains how to correctly orient an OBU and initiate testing using the T600 Tag Tester.
Describes the process for manually entering OBU bar code information if the scanner fails.
Guides users on how to configure the T600 to record OBU test results into specified log files.
Details available commands, their execution methods, purpose, and who can execute them.
Explains the calibration process performed by Kapsch service personnel to set test criteria for OBUs.
Describes how write tests function, including data writing and setting a reserved memory bit.
Details the burst tests that ensure consistent OBU reading and writing, specifying success rate requirements.
Outlines the necessary hardware and software specifications for the computer used with the T600 Tag Tester.
Guides users through the step-by-step installation process of the T600 software on a customer-supplied computer.
Provides instructions for connecting the T600 Tag Tester hardware components and optional accessories.
Details the specific cable connections required for the TTU, computer, and optional scanner.
Explains how to install or update the agency mapping file for the T600 Tag Tester.
Guides the configuration of communication settings between the computer, TTU, and internal scanner.
Details the process of installing optional calibration files unique to each tag tester for initial calibration.
Provides instructions on differentiating Interior OBU (G4E) from older FPT (G3B) using tag serial numbers.
Details how to distinguish Exterior OBU (FME) from the older LPT model using tag serial numbers.
Lists common error messages related to OBU failures, with descriptions of their causes.
Provides a flowchart to diagnose and resolve serial connection errors between the PC and the T600.
Offers a troubleshooting guide for errors related to the IR sensor detecting OBU position in the cradle.
Outlines steps to resolve errors where OBU bar code data does not match stored information.
Explains how to identify and resolve issues caused by missing calibration files for specific OBU types.
Describes a procedure to check the TTU's functionality when consistent 'No response from tag' errors occur.
Outlines the recommended schedule and tasks for preventive maintenance of the T600 Tag Tester.
Illustrates the correct orientation of the G4 OBU within the TTU cradle.
Provides an illustration showing the correct placement of the Flat Pack Transponder (FPT) in the TTU cradle.
Shows the correct orientation for the Front Mount Exterior (FME) OBU in the TTU cradle.
Illustrates the correct positioning of the Roof Mount FTP within the TTU cradle.
Depicts the correct orientation for the Front Mount OBU (Motorcycle) in the TTU cradle.
Illustrates the correct orientation for the High Occupancy Toll (HOT) OBU in the TTU cradle.