7.7 The appliance switches on and off
continuously
· Clean the high-pressure nozzle.
· Check whether the heating element is calcified
(see chap. 6).
· Attach a larger nozzle when using high-
pressure extension hoses.
7.8 Burner does not ignite
· The ignition sparks can be observed through
the inspection window in the burner cover.
The appliance has a continuous ignition., i.e.
even when operating with cold water an ignition
spark must be visible. Clean, adjust or replace
the ignition electrodes as required
Fill the fuel tank.
Check that the fuel pump and the fuel
solenoid valve function correctly.
Clean the strainer in the low-water safety
device (diagram 2).
Change the fuel filter.
Check the direction of rotation of the engine.
If the direction of rotation is correct, there
will be a powerful air flow from the exhaust
gas opening of the burner.
7.9 The temperature is not reached
when operating with hot water/steam
· Set the thermostat higher.
· Reduce the operating pressure and the flow
rate.
· Check whether the heating element is sooted
(see chap. 6).
7. Troubleshooting