EasyManua.ls Logo

Kärcher HDS Super - EACH TIME AFTER USAGE; Following operation with cleaning agent; Stopping machine

Kärcher HDS Super
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English HDS Super, HDS 655, HDS 695 S, HDS 895 S, HDS 1195 23
Operation with cold water
Removal of slight contamination and rinsing
e.g.: Garden implements, terrace, tools, etc.
Set operating pressure as required
Set the temperature regulator (item 24) to "0"
Operation with hot water
* Danger of scalding
Set the temperature regulator (item 24) to the
required temperature
We recommend the following cleaning
temperatures
Slight contamination 30-50°C
Protein soiling, e.g. in foodstuffs industry
max. 60°C
Motor vehicle cleaning, machine cleaning
60-90°C
Operation with steam
At operating temperatures above 98°C
operating pressure must not exceed 32 bar.
Standard high-pressure nozzle is therefore
to be replaced with steam nozzle (part no.:
4.766-023, for HDS 1195 4.766-024; see
accessories) be replaced.
Set operating pressure to minimum value.
See Figure 9
Set the temperature regulator (item 24) to
min. 100°C
* Danger of scalding!
We recommend the following cleaning
temperatures
Preservative removal, extremely greasy dirt
100-110°C
Thawing of aggregates, certain facade
cleaning operations up to 140°C
EACH TIME AFTER USAGE
Warning!
Danger of scalding with hot water.
After operating it with hot water or steam the
unit must be cooled for at least two minutes by
operating it with cold water and its open
handgun.
Following operation with cleaning agent
Set the cleaning agent metering valve
(item 30) to "0"
Set the unit switch (item 23) to "I"
Actuate handgun and flush unit for
approx. 1 min
Stopping machine
Set the unit switch (item 23) to "0"
Shut off water supply
Switch the pump briefly on with the unit switch
(item 23) (approx. 5 sec.)
Remove mains plug from socket ONLY with
dry hands
Detach water connection
Actuate handgun to depressurise unit
Lock the hand spray gun Figure 8
Engage spray lance in cover holder
Reel up the high-pressure hose and electric
cables and attach them to fastenings
* Take care not to kink high-pressure hose and
cable!
Frost will destroy unit if water is not drained off
completely!
Store unit in a frost-free location
Observe the following if the unit is connected to
a flue:
Danger of damage caused by cold air entering
through the flue. Disconnect unit from flue at
outside temperatures below 0°C.
Take unit out of service if frost-free storage is
not possible.

Other manuals for Kärcher HDS Super

Related product manuals