Authorization process
16/128
Status LED Function
Flashes orange slowly every 5
seconds
Temperature limit exceeded (charging procedure temporarily interrupted;
charging continues after cooling down)
Flashes red Malfunction (For details, see chapter "Troubleshooting")
Segment 1 lights up orange RFID programming mode (RFID cards can be programmed in this mode.
For details, see chapter "Programming RFID user cards (optional)")
Segment 2 lights up orange Commissioning mode
(the charging station is in commissioning mode)
2.2 Authorization (optional)
An (optional) authorization of a user for charging at the charging station can either occur with
a key switch or by means of RFID user cards depending on the device version.
Authorization required:
The status LED flashes blue slowly every 3 seconds.
Authorization successful:
A successful authorization will be indicated by a series of increasing tones.
Authorization failed:
A failed authorization will be indicated by a series of decreasing tones.
Note
After successful authorization, if the charging procedure is not started within 60seconds, the au-
tomatic enable expires.