P30 Readable Data
Modbus TCP Programmers Guide V1.02
12
© KEBA
Type and
features
Product
type
Cable /
Socket
Sup-
ported
current
Device
series
Energy
meter
Autho-
rization
No RFID 0
With RFID 1
1)
MID (Measuring Instruments Directive): Measuring Instruments Directive
Example:
Value 304111:
The charging station has the following type and features:
● KC-P30
● 32 A
● c-series
● standard energy meter, not calibrated
● with RFID
3.9 1018 - Firmware version
Note: In P30 Modbus TCP version 1.11, this register's number is 1013.
This register contains the firmware version of the charging station. The rep-
resented value is in decimal and has to be converted to hex in order to read
the firmware version.
Index Name Type Attr.
1018 Firmware UINT32 ro
Example:
Value 50990336 converted to hex = 30A0D00, which means firmware ver-
sion 3.10.14 (0A=10, 0D=14).
3.10 1020 - Active power
This register contains the active power in milliwatts.
Unit: mW
Index Name Type Attr.
1020 Active Power UINT32 ro
Example:
Value 98661: The active power of the charging station is 98661 mW =
98.661 W.