P30 Readable Data
Modbus TCP Programmers Guide V1.02
13
© KEBA
3.11 1036 - Total energy
This register contains the total energy consumption (persistent, device re-
lated) in watt-hours.
Unit: Wh
Index Name Type Attr.
1036 Energy Meter UINT32 ro
Example:
Value 38101: The total energy consumption of the charging station is: 38101
Wh = 38.101 kWh.
3.12 1040 - Voltage phase 1
This register contains the measured voltage value on phase 1 in volts.
Unit: V
Index Name Type Attr.
1040 U1 UINT32 ro
Example:
Value 230: The measured voltage value on phase 1 is 230 V.
3.13 1042 - Voltage phase 2
This register contains the measured voltage value on phase 2 in volts.
Unit: V
Index Name Type Attr.
1042 U2 UINT32 ro
Example:
Value 230: The measured voltage value on phase 2 is 230 V.
3.14 1044 - Voltage phase 3
This register contains the measured voltage value on phase 3 in volts.
Unit: V
Index Name Type Attr.
1044 U3 UINT32 ro
Example: